Endoscope decontamination: where do we go from here?
- PMID: 7560997
- DOI: 10.1016/0195-6701(95)90061-6
Endoscope decontamination: where do we go from here?
Abstract
Thorough cleaning and disinfection or sterilization of endoscopes and associated equipment will reduce the likelihood of misdiagnosis and post-procedural infection. It will also prevent instrument deterioration and malfunction. With a rapid escalation in demand for endoscopy, particularly that associated with minimally invasive surgery, it is important that we have the processing technology to match the diagnostic and therapeutic value of these instruments without exposing staff and patients to unnecessary risk. Wherever possible staff should purchase heat tolerant endoscopic equipment that is readily accessible for cleaning. Automated processors, e.g. washer disinfectors and ultrasonic cleaners, improve the quality of the decontamination process but machines must have a self-disinfect function to prevent instrument recontamination during processing. Sterile, or filtered bacteria-free, water is essential for bronchoscopes and invasive instruments. Glutaraldehyde is still the most widely used disinfectant, particularly for the heat sensitive flexible endoscopes, but it is irritant and sensitizing and a safer alternative is sought. Peracetic acid is more rapidly efficacious and probably less irritant and, provided it does not damage endoscopes and processing equipment, may prove a suitable alternative. Unfortunately there are no nationally agreed test methods for assessing this and other new endoscope disinfectants and therefore no register of suitable or approved products. There is also no proven safe alternative to ethylene oxide for sterilizing invasive heat labile flexible endoscopes. It is important that, if toxic disinfectants and sterilants are used, staff and patients are suitably protected from exposure. Update training is essential for all processing staff if infection risks are to be minimized and sensitization problems avoided.
Similar articles
-
Decontamination of minimally invasive surgical endoscopes and accessories.J Hosp Infect. 2000 Aug;45(4):263-77. doi: 10.1053/jhin.2000.0767. J Hosp Infect. 2000. PMID: 10973743
-
Endoscope decontamination: automated vs. manual.J Hosp Infect. 1995 Jun;30 Suppl:537-42. doi: 10.1016/0195-6701(95)90060-8. J Hosp Infect. 1995. PMID: 7560995
-
Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee.Gut. 1998 Apr;42(4):585-93. Gut. 1998. PMID: 9616326 Free PMC article.
-
The mechanics of endoscope disinfection.J Hosp Infect. 1991 Jun;18 Suppl A:130-5. doi: 10.1016/0195-6701(91)90014-y. J Hosp Infect. 1991. PMID: 1679775 Review.
-
Endoscopic decontamination: an audit and practical review.J Hosp Infect. 2002 Apr;50(4):261-8. doi: 10.1053/jhin.2002.1177. J Hosp Infect. 2002. PMID: 12014898 Review.
Cited by
-
British Thoracic Society guidelines on diagnostic flexible bronchoscopy.Thorax. 2001 Mar;56 Suppl 1(Suppl 1):i1-21. doi: 10.1136/thorax.56.suppl_1.i1. Thorax. 2001. PMID: 11158709 Free PMC article. No abstract available.
-
Correlations between available primary amines, endospore coat thickness, and alkaline glutaraldehyde sensitivity for spores of select Bacillus species.Microbiologyopen. 2020 Nov;9(11):e1117. doi: 10.1002/mbo3.1117. Epub 2020 Sep 29. Microbiologyopen. 2020. PMID: 32996289 Free PMC article.
-
Antimicrobial biocides in the healthcare environment: efficacy, usage, policies, and perceived problems.Ther Clin Risk Manag. 2005 Dec;1(4):307-20. Ther Clin Risk Manag. 2005. PMID: 18360573 Free PMC article.
-
Occult risk of broken instruments for endoscopy-assisted surgery.World J Surg. 2014 Nov;38(11):3015-22. doi: 10.1007/s00268-014-2666-0. World J Surg. 2014. PMID: 24952076
-
Potential biological indicators for glutaraldehyde and formaldehyde sterilization processes.J Ind Microbiol Biotechnol. 2003 Mar;30(3):135-40. doi: 10.1007/s10295-002-0007-z. Epub 2003 Mar 20. J Ind Microbiol Biotechnol. 2003. PMID: 12715249
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical