Localization of an ectopic parathyroid adenoma by double-phase technetium-99m-sestamibi scintigraphy
- PMID: 7562052
Localization of an ectopic parathyroid adenoma by double-phase technetium-99m-sestamibi scintigraphy
Abstract
Double-phase planar scintigraphy using 99mTc-MIBI has been introduced as a means to detect and localize parathyroid adenomas. Focal uptake on both early and delayed imaging is typical of these entities. We report a patient with persistent hypercalcemia following subtotal parathyroidectomy, who was found scintigraphically to have an ectopic parathyroid adenoma. Following initial detection within the mediastinum using planar scintigraphy, the adenoma was more precisely localized using SPECT imaging. This case suggests that double-phase parathyroid planar scintigraphy augmented with SPECT imaging, if needed, is cost-effective, and often necessary, in the assessment of primary hyperparathyroid patients before surgical reexploration.
Similar articles
-
[Ectopic parathyroid adenoma: Scintigraphic detection and radioguided surgery].Rev Esp Med Nucl. 2011 Jan-Feb;30(1):19-23. doi: 10.1016/j.remn.2010.09.003. Epub 2011 Jan 3. Rev Esp Med Nucl. 2011. PMID: 21208692 Spanish.
-
Radio-guided surgical excision of an ectopic mediastinal parathyroid adenoma demonstrated on Tc-99m sestamibi hybrid imaging.Intern Med J. 2009 Apr;39(4):263-4. doi: 10.1111/j.1445-5994.2009.01901.x. Intern Med J. 2009. PMID: 19220551 No abstract available.
-
Technetium-99m-sestamibi SPECT localization of mediastinal parathyroid adenoma.J Nucl Med. 1996 Sep;37(9):1535-7. J Nucl Med. 1996. PMID: 8790213
-
[99m Tc-sestamibi in the diagnosis of the location of hyperparathyroidism].Rev Esp Med Nucl. 1998;17(2):102-11. Rev Esp Med Nucl. 1998. PMID: 9611280 Review. Spanish. No abstract available.
-
Multimodality imaging of the parathyroid glands in primary hyperparathyroidism.Minerva Endocrinol. 2008 Sep;33(3):193-202. Minerva Endocrinol. 2008. PMID: 18846025 Review.
Cited by
-
Localization of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imaging.Eur J Nucl Med. 1997 Feb;24(2):197-201. doi: 10.1007/BF02439553. Eur J Nucl Med. 1997. PMID: 9021118
-
Comparison and histopathological correlation of three parathyroid imaging methods in a population with a high prevalence of concomitant thyroid diseases.Eur J Nucl Med. 1997 Feb;24(2):143-9. doi: 10.1007/BF02439546. Eur J Nucl Med. 1997. PMID: 9021111
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources