Field trial of a three-dimensional activity monitor: comparison with self report
- PMID: 7564975
- DOI: 10.1249/00005768-199507000-00017
Field trial of a three-dimensional activity monitor: comparison with self report
Abstract
We examined the ability of the Tritrac-R3D to estimate daily energy expenditure (EE) and characterize the physical activity patterns of free-living humans. Daily EE was estimated by the Tritrac, a 3-d physical activity log (PAL), and a 7-d recall (SDR). Digital storage of activity data by the Tritrac allowed us to tabulate the number of minutes the monitor recorded EE at specific activity intensities. Twenty-five men and women (mean age and body mass 26.7 yr, 72.5 kg) wore the monitor for 7 d. The Tritrac significantly underestimated daily EE compared with the PAL and SDR, 2552.7 vs 2915.5 kcal.d-1 and 2530.0 vs 2840.3 kcal.d-1, respectively (both, P < 0.01). Correlations between the Tritrac and PAL and the SDR were r = 0.82 and r = 0.77 (both, P < 0.001). Compared with the PAL, the Tritrac overestimated time accumulated in sedentary activities (862.7 vs 827.2 min.d-1) but underestimated time accumulated in active behaviors (37.5 vs 78.0 min.d-1). In conclusion, these data suggest the Tritrac ranks activity levels similarly to the PAL and SDR but it significantly underestimates free-living energy expenditure.
Similar articles
-
Comparison of the TriTrac-R3D accelerometer and a self-report activity diary with heart-rate monitoring for the assessment of energy expenditure in children.Br J Nutr. 2002 Jun;87(6):623-31. doi: 10.1079/BJNBJN2002571. Br J Nutr. 2002. PMID: 12067433
-
Comparison of a computerized physical activity recall with a triaxial motion sensor in middle-school youth.Med Sci Sports Exerc. 1998 Aug;30(8):1238-45. doi: 10.1097/00005768-199808000-00009. Med Sci Sports Exerc. 1998. PMID: 9710863
-
The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure.Med Sci Sports Exerc. 1999 May;31(5):747-54. doi: 10.1097/00005768-199905000-00020. Med Sci Sports Exerc. 1999. PMID: 10331898
-
Field evaluation of energy expenditure in women using Tritrac accelerometers.Med Sci Sports Exerc. 2002 Oct;34(10):1667-74. doi: 10.1097/00005768-200210000-00020. Med Sci Sports Exerc. 2002. PMID: 12370570
-
Maximal sustained levels of energy expenditure in humans during exercise.Med Sci Sports Exerc. 2011 Dec;43(12):2359-67. doi: 10.1249/MSS.0b013e31822430ed. Med Sci Sports Exerc. 2011. PMID: 21606870 Review.
Cited by
-
Exercise Physiology From 1980 to 2020: Application of the Natural Sciences.Kinesiol Rev (Champaign). 2021 Aug;10(3):238-247. doi: 10.1123/kr.2021-0024. Epub 2021 Jun 30. Kinesiol Rev (Champaign). 2021. PMID: 35464337 Free PMC article.
-
Lies, Damned Lies, and Survey Self-Reports? Identity as a Cause of Measurement Bias.Soc Psychol Q. 2016 Dec;79(4):333-354. doi: 10.1177/0190272516628298. Epub 2016 Nov 18. Soc Psychol Q. 2016. PMID: 29038609 Free PMC article.
-
Measurement of physical activity in children with particular reference to the use of heart rate and pedometry.Sports Med. 1997 Oct;24(4):258-72. doi: 10.2165/00007256-199724040-00004. Sports Med. 1997. PMID: 9339494 Review.
-
A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review.Int J Behav Nutr Phys Act. 2008 Nov 6;5:56. doi: 10.1186/1479-5868-5-56. Int J Behav Nutr Phys Act. 2008. PMID: 18990237 Free PMC article.
-