The impact of the implantable cardioverter defibrillator on quality-of-life
- PMID: 7567594
- DOI: 10.1111/j.1540-8159.1995.tb02603.x
The impact of the implantable cardioverter defibrillator on quality-of-life
Abstract
The implantable cardioverter defibrillator (ICD) is an established treatment for patients with life-threatening ventricular arrhythmias. While it clearly reduces the incidence of death from recurrent arrhythmia, little is known about the impact on patients' quality-of-life. In this prospective study, quality-of-life was assessed by questionnaire before and after ICD implantation. The "Sickness Impact Profile" (SIP), which evaluates physical, psychosocial, and other activities, as well as functions of daily life, was used. Employment and rehospitalization rates were also examined. Twenty-one of 23 consecutive patients, aged 58 +/- 11 years, undergoing ICD implantation at Royal Perth Hospital were studied. During the 14 +/- 8 month follow-up, 4 patients died. Functional capacity was unchanged in all but one of the survivors in whom it improved from New York Heart Association Class III to II. Four of 8 survivors employed before implant have since retired. Six patients required rehospitalization on 13 occasions, problems related to arrhythmias or the ICD. Overall SIP scores preimplant (11.2 +/- 9.3; P < 0.05) were significantly worse at 6-month follow-up (21.7 +/- 18.2), but returned to preimplant levels by 12-month follow-up (8.8 +/- 10.8; NS). This was primarily due to transient problems in the areas of emotional behavior, alertness, and social interaction. SIP psychosocial dimension scores: preimplant: 7.2 +/- 9.0; 6-month: 17.8 +/- 18.1 (P < 0.05); and 12-month: 8.6 +/- 10.3 (NS). Early retirement and hospitalizations due to arrhythmias may still be expected even after implantation of an ICD; however, quality-of-life appears only to temporarily decline.
Similar articles
-
Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society.Circulation. 1993 Mar;87(3):800-7. doi: 10.1161/01.cir.87.3.800. Circulation. 1993. PMID: 8443901
-
Long-term clinical outcome in patients with severe left ventricular dysfunction and an implantable cardioverter-defibrillator after ventricular tachyarrhythmias.Rev Port Cardiol. 2005 Apr;24(4):487-98. Rev Port Cardiol. 2005. PMID: 15977773 English, Portuguese.
-
Determinants of the quality of life (QoL) in patients with an implantable cardioverter/defibrillator (ICD).Qual Life Res. 2004 Mar;13(2):411-6. doi: 10.1023/B:QURE.0000018493.32844.56. Qual Life Res. 2004. PMID: 15085913
-
[Good experiences with an implantable automatic defibrillator with transvenous electrodes for patients with life-threatening arrhythmias].Ned Tijdschr Geneeskd. 1997 Jul 26;141(30):1475-80. Ned Tijdschr Geneeskd. 1997. PMID: 9542881 Dutch.
-
Rehabilitation of patients with implantable cardioverter/defibrillator: a literature review.Acta Cardiol. 2008 Apr;63(2):249-57. doi: 10.2143/AC.63.2.2029535. Acta Cardiol. 2008. PMID: 18468207 Review.
Cited by
-
Effects of mobile telephones on the function of implantable cardioverter defibrillators.Ann Noninvasive Electrocardiol. 2005 Oct;10(4):409-13. doi: 10.1111/j.1542-474X.2005.00057.x. Ann Noninvasive Electrocardiol. 2005. PMID: 16255750 Free PMC article. Clinical Trial.
-
Phantom shocks unmasked: clinical data and proposed mechanism of memory reactivation of past traumatic shocks in patients with implantable cardioverter defibrillators.J Interv Card Electrophysiol. 2012 Aug;34(2):205-13. doi: 10.1007/s10840-011-9640-7. Epub 2011 Dec 21. J Interv Card Electrophysiol. 2012. PMID: 22183617
-
Quality of life and psychological status of patients with implantable cardioverter defibrillators.J Interv Card Electrophysiol. 2006 Oct;17(1):65-72. doi: 10.1007/s10840-006-9053-1. Epub 2007 Jan 18. J Interv Card Electrophysiol. 2006. PMID: 17235681
-
[Internet therapy for ICD-patients].Herzschrittmacherther Elektrophysiol. 2011 Sep;22(3):166-73. doi: 10.1007/s00399-011-0145-y. Herzschrittmacherther Elektrophysiol. 2011. PMID: 21826541 Review. German.
-
Impairment of Quality of Life among Patients with Wearable Cardioverter Defibrillator Therapy (LifeVest®): A Preliminary Study.Biomed Res Int. 2018 Jun 27;2018:6028494. doi: 10.1155/2018/6028494. eCollection 2018. Biomed Res Int. 2018. PMID: 30050939 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous