Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT)
- PMID: 7585237
- DOI: 10.3109/09286589509057085
Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT)
Abstract
The Roche European-American Anticataract Trial (REACT) will assess the effect of antioxidants on progression of cataract in humans. This report evaluates the methods used in REACT. Seventy three subjects (139 eyes) with cortical (C), posterior subcapsular (P), nuclear (N) or mixed cataract were seen twice within two weeks for eye examinations, assessments of visual function, lens photographs and CCD images. The degree of cataract and nuclear color (NC) were assessed with subjective (LOCS III) and objective (computerized, CASE 2000 CCD) methods. Repeat visit values were used to calculate intraclass correlation coefficients (r1) and 95% tolerance limits (TL). A clinically significant change (CSC) was defined as one step in LOCS III. The relative power of each method to detect cataract change and sample sizes needed to achieve statistically significant results were calculated. The r1 values for visual function tests ranged from 0.76 to 0.88; if these tests of visual function were used to detect a clinically significant change in cataract severity, sample sizes of 840 to 2707 per group would be needed. The r1 values for LOCS III were 0.88 to 0.97, and sample sizes ranged from 50 to 135 per group. The r1 values for the CCD were 0.93 to 0.98, and sample sizes ranged from 1 to 42 with poorer values relating to measurement of P. We conclude that the methods used in REACT are reproducible. The analytical algorithms in the image analysis programs did not permit differentiation between C and P opacification; therefore, P cataract is best measured with LOCS III. REACT sample sizes are adequate to detect a difference of 0.2 LOCS III units/year between the mean rates of cataract progression in two groups.
Comment in
-
Quantify measurement error in assessing severity of cataract.Ophthalmic Epidemiol. 1996 Jun;3(2):59-60. doi: 10.3109/09286589609080109. Ophthalmic Epidemiol. 1996. PMID: 8841056 No abstract available.
Similar articles
-
Comparison of methods to identify incident cataract in eyes of patients with neovascular maculopathy: Submacular Surgery Trials Report No. 18.Ophthalmology. 2008 Jan;115(1):127-33. doi: 10.1016/j.ophtha.2007.03.027. Epub 2007 Jun 14. Ophthalmology. 2008. PMID: 17574675 Clinical Trial.
-
Correlation of nuclear cataract lens density using Scheimpflug images with Lens Opacities Classification System III and visual function.Ophthalmology. 2009 Aug;116(8):1436-43. doi: 10.1016/j.ophtha.2009.03.002. Epub 2009 Jun 4. Ophthalmology. 2009. PMID: 19500847
-
Objective line spread function measurements, Snellen acuity, and LOCS II classification in patients with cataract.Optom Vis Sci. 1993 Nov;70(11):956-62. doi: 10.1097/00006324-199311000-00013. Optom Vis Sci. 1993. PMID: 8302532
-
Contrast acuity in cataracts of different morphology and association to self-reported visual function.Invest Ophthalmol Vis Sci. 2006 Dec;47(12):5412-22. doi: 10.1167/iovs.05-1564. Invest Ophthalmol Vis Sci. 2006. PMID: 17122131
-
Quantitating cataract and nuclear brunescence, the Harvard and LOCS systems.Optom Vis Sci. 1993 Nov;70(11):886-95. doi: 10.1097/00006324-199311000-00005. Optom Vis Sci. 1993. PMID: 8302524
Cited by
-
Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction.Clin Ophthalmol. 2016 Apr 6;10:609-15. doi: 10.2147/OPTH.S95993. eCollection 2016. Clin Ophthalmol. 2016. PMID: 27103780 Free PMC article.
-
Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.Int Ophthalmol. 2018 Jun;38(3):1103-1110. doi: 10.1007/s10792-017-0566-7. Epub 2017 May 26. Int Ophthalmol. 2018. PMID: 28550347
-
Cataract Grading in Pure Senile Cataracts: Pentacam versus LOCS III.J Ophthalmic Vis Res. 2022 Aug 15;17(3):337-343. doi: 10.18502/jovr.v17i3.11570. eCollection 2022 Jul-Sep. J Ophthalmic Vis Res. 2022. PMID: 36160089 Free PMC article.
-
Evaluation of optimized digital fundus reflex photographs for lens opacities in the age-related eye disease study 2: AREDS2 report 7.Invest Ophthalmol Vis Sci. 2013 Sep 5;54(9):5989-94. doi: 10.1167/iovs.13-12301. Invest Ophthalmol Vis Sci. 2013. PMID: 23887802 Free PMC article.
-
A randomized, placebo-controlled, clinical trial of high-dose supplementation with vitamins C and E and beta carotene for age-related cataract and vision loss: AREDS report no. 9.Arch Ophthalmol. 2001 Oct;119(10):1439-52. doi: 10.1001/archopht.119.10.1439. Arch Ophthalmol. 2001. PMID: 11594943 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical