Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Aug;27(1):131-9.
doi: 10.1006/faat.1995.1116.

Immunosuppressive activity of polychlorinated biphenyl mixtures and congeners: nonadditive (antagonistic) interactions

Affiliations

Immunosuppressive activity of polychlorinated biphenyl mixtures and congeners: nonadditive (antagonistic) interactions

N Harper et al. Fundam Appl Toxicol. 1995 Aug.

Abstract

The dose-response inhibition of the splenic plaque-forming cell (PFC) response and serum IgM units to the antigen, trinitrophenyl-lipopolysaccharide, was determined for several polychlorinated biphenyl (PCB) mixtures and congeners in female B3C3F1 mice. The ED50 values for Aroclor 1260-, 1254-, 1248-, and 1242-induced immunotoxicity varied by less than twofold from 355 to 699 mg/kg. The range of ED50 values for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 3,3',4,4'-tetrachlorobiphenyl, 3,3',4,4',5-pentaCB, 3,3',4,4',5,5'-hexaCB, 2,3,3',4,4'-pentaCB, 2,3',4,4',5-pentaCB, 2,3,3',4,4',5-hexaCB, 2,3,3',4,4',5,5'-heptaCB, 2,2',3,3',4,4',5-heptaCB, and 2,2',3,4,4',5,5'-heptaCB were 4.6 to 4.9, 134 to 245, 4.7 to 7.0, 6.9 to 11.1, 88,000 to 121,000, 122,000 to 132,000, 99,000 to 157,000, 89,000 to 129,000, 117,000 to 240,000, and 132,000 to 238,000 micrograms/kg, respectively. The immunotoxicity-derived toxic equivalency factors (TEFs) for these congeners could be calculated from the ED50 (TCDD)/ED50 (congener) ratios and the TEF values were within the range of those previously determined for other aryl hydrocarbon receptor-mediated responses. Based on the known concentrations of these congeners in the PCB mixtures, TCDD or toxic equivalents (TEQs) in the mixture were calculated [i.e., TEQ = sigma (PCBcongener x TEF)] using the immunotoxicity-derived TEFs (plaque-forming cells/10(6) viable cells). TEQ values for Aroclors 1260, 1254, 1248, and 1242 were 16.0, 54.4, 260.4, and 197 ppm, respectively. Based on the ED50 value for the immunosuppressive activity of TCDD (4.8 micrograms/kg), the calculated ED50 values for immune suppression by Aroclors 1260, 1254, 1248, and 1242 were 300, 88, 18, and 24 mg/kg, respectively. The ED50 (observed)/ED50 (calculated) ratios were 1.2, 5.9, 21, and 22.0 for Aroclors 1260, 1254, 1248 and 1242, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources