Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis
- PMID: 7600650
- DOI: 10.1161/01.cir.92.2.190
Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis
Abstract
Background: Less invasive methods are replacing traditional invasive means of measuring coronary flow reserve (CFR). Transesophageal echocardiography (TEE) is becoming a useful tool for evaluation of coronary artery disease and has recently been used to measure CFR. This has always been done using dipyridamole, but adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole. This study was done to evaluate the hypothesis that adenosine is safe, rapid, and accurate in measuring coronary blood flow reserve by TEE Doppler.
Methods and results: Forty-nine patients who had recently undergone angiography had a transesophageal echocardiogram with visualization of the coronary arteries and measurement of blood flow velocity in the left anterior descending coronary artery (LAD) during adenosine infusion of 0.14 mg/kg per minute. Angiograms were analyzed by quantitative coronary angiography, and significant stenosis was defined as > 70% lumenal diameter narrowing. Thirty-nine of the 49 patients did not have a significant LAD stenosis (group 1); the remainder had significant disease (group 2). Good spectral Doppler recordings of blood flow velocity in the LAD were obtained in 41 of 46 patients (89%). There were no significant differences in baseline coronary blood flow velocities between the two groups. Hyperemic to baseline flow ratios were significantly higher in patients without significant LAD stenosis for peak (2.83 +/- 1.04 versus 1.78 +/- 0.36) and mean (2.68 +/- 0.96 versus 1.75 +/- 0.39) diastolic velocity. A CFR ratio > 2.1 had a sensitivity of 86%, a specificity of 79%, a positive predictive value of 46%, and a negative predictive value of 96% for the absence of critical LAD stenosis. The infusion was well tolerated. It had to be prematurely terminated in only 3 patients (6.5%), and they were asymptomatic. No patient experienced chest pain, palpitations, or flushing. Intraobserver and interobserver variabilities were low, and reproducibility of data was good (< 4%).
Conclusions: Adenosine Doppler TEE is an effective, rapid, safe, and superior means of measuring CFR ratio. This method is convenient for serial measurements of CFR as well as in clinical settings such as evaluation of syndrome X, cardiomyopathy, and aortic regurgitation.
Similar articles
-
Reduction of coronary flow reserve non-invasively determined by transthoracic Doppler echocardiography as a predictor of left anterior descending coronary artery stenosis.Ital Heart J. 2000 Apr;1(4):289-94. Ital Heart J. 2000. PMID: 10824730
-
Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography.Circulation. 1998 Apr 28;97(16):1557-62. doi: 10.1161/01.cir.97.16.1557. Circulation. 1998. PMID: 9593560
-
Simultaneous transesophageal Doppler assessment of coronary flow reserve in the left anterior descending artery and coronary sinus allows differentiation between proximal and non-proximal left anterior descending artery stenoses.Eur J Echocardiogr. 2004 Jan;5(1):25-33. doi: 10.1016/s1525-2167(03)00047-7. Eur J Echocardiogr. 2004. PMID: 15113009
-
[Intravenous adenosine infusion in the assessment of coronary flow reserve in hypertension. Transesophageal Doppler echocardiographic study].Orv Hetil. 1999 Mar 7;140(10):523-7. Orv Hetil. 1999. PMID: 10323067 Review. Hungarian.
-
Transthoracic Doppler echocardiography - noninvasive diagnostic window for coronary flow reserve assessment.Cardiovasc Ultrasound. 2003 Apr 11;1:4. doi: 10.1186/1476-7120-1-4. Cardiovasc Ultrasound. 2003. PMID: 12740038 Free PMC article. Review.
Cited by
-
Coronary flow reserve impairment in apical vs asymmetrical septal hypertrophic cardiomyopathy.Clin Cardiol. 2013 Apr;36(4):207-16. doi: 10.1002/clc.22095. Epub 2013 Feb 3. Clin Cardiol. 2013. PMID: 23378014 Free PMC article.
-
[Methods for coronary functional assessment].Herz. 1998 Mar;23(2):78-96. doi: 10.1007/BF03044539. Herz. 1998. PMID: 9592704 Review. German.
-
Using multidetector computed tomography in a swine model to assess the effects of sublingual nitroglycerin and intravenous adenosine on epicardial coronary arteries.Comp Med. 2009 Dec;59(6):573-9. Comp Med. 2009. PMID: 20034433 Free PMC article.
-
MR-based coronary artery blood velocity measurements in patients without coronary artery disease.Eur Radiol. 2006 May;16(5):1124-30. doi: 10.1007/s00330-005-0039-7. Epub 2006 Jan 13. Eur Radiol. 2006. PMID: 16411084
-
Comparison of transesophageal Doppler coronary flow reserve measurements with thallium-201 single-photon emission computed tomography imaging in assessment of left anterior descending artery stenoses.Clin Cardiol. 1998 Apr;21(4):247-52. doi: 10.1002/clc.4960210404. Clin Cardiol. 1998. PMID: 9562934 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources