A sensitive and reliable method for assaying true human insulin without interaction with human proinsulin-like molecules
- PMID: 7612920
- DOI: 10.1007/BF00581048
A sensitive and reliable method for assaying true human insulin without interaction with human proinsulin-like molecules
Abstract
In the present study our interests focused on the evaluation of a high capacity assay (MEIA) which allows true insulin determinations in the absence of cross-reactivity with proinsulin-like molecules. This method was compared to a commercially available radioimmunoassay (RIA) for insulin determination. As the latter gives insulin levels which represent a mixture of insulin and proinsulin-like molecules, the proinsulin-like molecules were quantitated by subtracting the true insulin levels measured using MEIA from the total insulin levels obtained using RIA. These methods were applied for the analysis of blood samples drawn in 63 normal subjects, 16 obese subjects, 3 patients submitted to islet transplantation and 4 patients with insulinoma. The MEIA was precise, fully automated and time-saving, making its application on a routine basis particularly attractive. MEIA and RIA were equally able to correctly quantify human insulin molecules. On the contrary, the antibody present in the true insulin assay did not interact with proinsulin-like molecules, which were recognized even in the presence of increasing insulin levels. In normal subjects, the true and total insulin levels in the fasting state and at the time peak after glucose- or arginine-induced endogenous insulin release were well correlated at r = 0.88 and 0.89, respectively. Interestingly, total insulin values were overestimated by 10%-16% as compared with true insulin levels, which represent proinsulin values superimposable on previously reported data. Proinsulin-like molecules made up 50% of the total insulin in obese and transplanted patients, and about 70% in patients with insulinoma.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Comparison of a radioimmunoassay with a microparticle enzyme immunoassay of insulin for use with the minimal model method of determining whole-body insulin sensitivity.Diabetes Technol Ther. 1999 Winter;1(4):463-8. doi: 10.1089/152091599317017. Diabetes Technol Ther. 1999. PMID: 11474834
-
The effect of exogenous hyperinsulinemia on proinsulin secretion in normal man, obese subjects, and patients with insulinoma.J Clin Endocrinol Metab. 1986 Nov;63(5):1117-20. doi: 10.1210/jcem-63-5-1117. J Clin Endocrinol Metab. 1986. PMID: 3020076
-
Highly specific radioimmunoassay for human insulin based on immune exclusion of all insulin precursors.Clin Chem. 1998 Jul;44(7):1504-13. Clin Chem. 1998. PMID: 9665430
-
Beta-cell adenomas without hyperinsulinemia with use of highly specific insulin radioimmunoassays: case report and review of literature.Endocr Pract. 2010 Jul-Aug;16(4):660-3. doi: 10.4158/EP10016.CR. Endocr Pract. 2010. PMID: 20439243 Review.
-
Insulin secretion in obese and non-obese NIDDM.Diabetes Res Clin Pract. 1995 Aug;28 Suppl:S27-37. doi: 10.1016/0168-8227(95)01083-p. Diabetes Res Clin Pract. 1995. PMID: 8529516 Review.
Cited by
-
The Relationship between Dietary, Serum and Hair Levels of Minerals (Fe, Zn, Cu) and Glucose Metabolism Indices in Obese Type 2 Diabetic Patients.Biol Trace Elem Res. 2019 May;189(1):34-44. doi: 10.1007/s12011-018-1470-3. Epub 2018 Aug 8. Biol Trace Elem Res. 2019. PMID: 30091069 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Research Materials