Retention of styrene following controlled exposure to constant and fluctuating air concentrations
- PMID: 7622276
- DOI: 10.1007/BF00383129
Retention of styrene following controlled exposure to constant and fluctuating air concentrations
Abstract
An experiment was designed to determine whether the respiratory retention of styrene vapor, as estimated from measurements of end-exhaled air, was the same during periods of both constant and fluctuating exposure. Six human subjects were exposed to styrene inside a experimental chamber. A computer-controlled system was used to generate time-varying air concentrations of styrene over 4-5h in both multistep sequences of constant exposure (four subjects exposed to 15-99 ppm of styrene in 100-min steps) and fluctuating patterns representative of occupational exposures (two subjects exposed to mean concentrations of styrene of 50 ppm). In the latter case, lognormally distributed exposures, which fit one of two first-order autoregressive models, were generated at intervals of 2.5 min. It was found that the concentration of styrene in end-exhaled air was reduced by about half if the subject inhaled one to three breaths of clean air prior to sampling. This suggests that significant amounts of styrene were desorbed from the lining of the lungs during the initial exhalation. The retention of styrene vapor during constant exposures was 0.935 and was independent of the level. During each of the two sets of fluctuating exposure the retention of styrene was also constant and was independent of both the variance and autocorrelation coefficient. However, the retention of styrene during the fluctuating exposure (estimates ranged from 0.957 to 0.973) was significantly higher than that observed during the constant exposures.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Species-specific pharmacokinetics of styrene in rat and mouse.Arch Toxicol. 1993;67(8):517-30. doi: 10.1007/BF01969264. Arch Toxicol. 1993. PMID: 8285850
-
Comparison of average estimated metabolic rates for styrene in previously exposed and unexposed groups with pharmacokinetic modelling.Occup Environ Med. 1996 Sep;53(9):601-5. doi: 10.1136/oem.53.9.601. Occup Environ Med. 1996. PMID: 8882117 Free PMC article.
-
Inhalation pharmacokinetics: evaluating systemic extraction, total in vivo metabolism, and the time course of enzyme induction for inhaled styrene in rats based on arterial blood:inhaled air concentration ratios.Toxicol Appl Pharmacol. 1984 Mar 30;73(1):176-87. doi: 10.1016/0041-008x(84)90065-6. Toxicol Appl Pharmacol. 1984. PMID: 6710514
-
Evaluation of long-term occupational exposure to styrene vapor on olfactory function.Chem Senses. 2007 Oct;32(8):739-47. doi: 10.1093/chemse/bjm041. Epub 2007 Jun 29. Chem Senses. 2007. PMID: 17602142
-
A field method for measuring solvent vapors in exhaled air--application to styrene exposure.Scand J Work Environ Health. 1991 Jun;17(3):195-204. doi: 10.5271/sjweh.1710. Scand J Work Environ Health. 1991. PMID: 2068559
Cited by
-
PKQuest: volatile solutes - application to enflurane, nitrous oxide, halothane, methoxyflurane and toluene pharmacokinetics.BMC Anesthesiol. 2002 Aug 15;2(1):5. doi: 10.1186/1471-2253-2-5. BMC Anesthesiol. 2002. PMID: 12182764 Free PMC article.
-
Predictors of occupational exposure to styrene and styrene-7,8-oxide in the reinforced plastics industry.Occup Environ Med. 2006 Oct;63(10):707-12. doi: 10.1136/oem.2005.025205. Epub 2006 Jun 6. Occup Environ Med. 2006. PMID: 16757507 Free PMC article.
-
Environmental and biological monitoring of benzene during self-service automobile refueling.Environ Health Perspect. 2000 Dec;108(12):1195-202. doi: 10.1289/ehp.001081195. Environ Health Perspect. 2000. PMID: 11133401 Free PMC article.