Coronary artery damage during mitral valve replacement
- PMID: 7629211
Coronary artery damage during mitral valve replacement
Abstract
An anatomic study of 15 hearts has assessed the existing correlations between the mitral annulus and coronary arteries. The circumflex artery is sometimes located very close to the mitral annulus, as close as one millimetre, hence there is a risk of injury during mitral valvular replacement. This risk is especially when coronaries have a prevailing left anatomic position or a balanced coronary system.
Comment in
-
Partial circumflex artery injury during mitral valve replacement: late presentation.J Cardiovasc Surg (Torino). 2000 Apr;41(2):333-4. J Cardiovasc Surg (Torino). 2000. PMID: 10901549 No abstract available.