Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor
Abstract
A spilldown correction method is proposed for the thallium-201 window image in simultaneous dual-isotope technetium-99m/thallium-201 single-photon emission tomographic (SPET) imaging based on a single acquisition into three energy windows. In this method, images are simultaneously acquired in two standard energy windows over the 99mTc and 201Tl photopeak regions and a third spilldown window adjacent to the 201Tl window. Using a Monte Carlo simulation of SPET, the fractional amount of 99mTc and 201Tl spilldown in the 201Tl window with respect to the total counts from the spilldown window, k12, was calculated for simulated images of point sources at varying depths within a water-filled elliptical tub phantom. When applied to experimental acquisitions, k12, multiplied by the total counts from the spilldown window, is then subtracted from the 201Tl window image to produce the corrected image. However, for successful applications in SPET, k12 must be determined on a projection-by-projection basis since k12 is depth dependent. Thus, a regression relation was obtained between k12 and the total count ratio of the spilldown to 99mTc windows, k23. The spilldown correction method was applied to 201Tl photopeak images of an extended source distribution in uniform and nonuniform attenuating media with dual-isotope 99mTc/201Tl and single-isotope 201Tl. A marked improvement in image contrast was observed between the corrected and uncorrected 201Tl window images. The average count ratio of uncorrected dual-isotope 201Tl/single-isotope 201Tl was 3.08 for uniform and 2.99 for non-uniform attenuating media.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Comparison of correction techniques for simultaneous 201Tl/99mTc myocardial perfusion SPECT imaging: a dog study.Phys Med Biol. 2000 Nov;45(11):N167-76. doi: 10.1088/0031-9155/45/11/405. Phys Med Biol. 2000. PMID: 11098924
-
Clinical value of triple-energy window scatter correction in simultaneous dual-isotope single-photon emission tomography with 123I-BMIPP and 201Tl.Eur J Nucl Med. 1997 Sep;24(9):1099-106. doi: 10.1007/BF01254240. Eur J Nucl Med. 1997. PMID: 9283101
-
Three-window transformation cross-talk correction for simultaneous dual-isotope imaging.J Nucl Med. 1997 Dec;38(12):1992-8. J Nucl Med. 1997. PMID: 9430484
-
[201Tl, 99mTc-PYP dual SPECT].Nihon Rinsho. 1994 Jul;52 Suppl(Pt 1):579-85. Nihon Rinsho. 1994. PMID: 12436585 Review. Japanese. No abstract available.
-
Technetium, the missing element.Eur J Nucl Med. 1996 Mar;23(3):336-44. doi: 10.1007/BF00837634. Eur J Nucl Med. 1996. PMID: 8599967 Review.
Cited by
-
99mTc/123I Dual-Radionuclide Correction for Self-Scatter, Down-Scatter, and Tailing Effect for a CZT SPECT with Varying Tracer Distributions.IEEE Trans Radiat Plasma Med Sci. 2023 Nov;7(8):839-850. doi: 10.1109/trpms.2023.3297443. Epub 2023 Jul 27. IEEE Trans Radiat Plasma Med Sci. 2023. PMID: 38745858 Free PMC article.
-
Monte Carlo-based down-scatter correction of SPECT attenuation maps.Eur J Nucl Med Mol Imaging. 2004 Aug;31(8):1173-81. doi: 10.1007/s00259-004-1507-z. Epub 2004 Mar 18. Eur J Nucl Med Mol Imaging. 2004. PMID: 15034678
-
Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.Phys Med Biol. 1999 Jul;44(7):1843-60. doi: 10.1088/0031-9155/44/7/319. Phys Med Biol. 1999. PMID: 10442716 Free PMC article.
-
Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner.Phys Med Biol. 2011 Mar 7;56(5):1397-414. doi: 10.1088/0031-9155/56/5/012. Epub 2011 Feb 11. Phys Med Biol. 2011. PMID: 21317483 Free PMC article.
-
Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.J Nucl Cardiol. 2001 Mar-Apr;8(2):144-51. doi: 10.1067/mnc.2001.111799. J Nucl Cardiol. 2001. PMID: 11295691