[Biomechanical testing of the new torque-segmented arch (TSA)]
- PMID: 7649516
- DOI: 10.1007/BF02168135
[Biomechanical testing of the new torque-segmented arch (TSA)]
Abstract
New torque-segmented arch wires are presented which consist of a superelastic anterior component with 30 degrees or 45 degrees torque and which are connected to 2 steel lateral components by means of a crimped connector. When using such torque-segmented arch wires, the crimped connector rests mesially to the canine bracket and the lateral components exhibit a torque of 0 degree. The use of the torque-segmented arch wires requires the practitioner to adjust the anterior tooth segment, to bend in first order bends in the steel lateral portion as well as to bend in a sweep to avoid an anterior tooth extrusion, and, if desired, to bend in third order bends to influence premolars and molars. In some cases the simultaneous application of palatal arches can become necessary, because each torque transfer results in a transversal enlargement in the molar area. Compared to conventional steel wires with dimensions of 0.016 x 0.022 in which an anterior tooth torque is bent, the torque segmented arch wires exhibit considerably fewer side effects, but there is a larger distally rotating moment for the molars. 1. When applying torque-segmented arch wires, the extrusive force transferred to the anterior teeth is considerably smaller. 2. The protrusive force acting on the anterior teeth is also considerably smaller, which results in a reduced demand being placed on the anchorage of the molars. 3. The torque transfer to the incisors rests in a quite moderate range, even in the case of a 50 degrees torque. For this reason, the practitioner can expect diminished or no resorptions at all compared to the aforementioned steel wires. 4. The Martensite plateau of the torque-segmented arch wires exhibit constant moments in large areas so that such arch wires can be used in almost every anterior tooth position. 5. The segmented wires presented here can be applied not only in the case of the standard edgewise technique but also in each case of the straight-wire technique. 6. These new arch wires require no readjustment of torque values. 7. To control the transferred torque values it is recommended that the already transferred torque values be monitored during each check-up with the help of the described torque key. 8. When the torque values of the brackets are known, the torque key renders frequent patient X-rays superfluous. 9. When the desired torque values are attained, treatment can proceed using conventional arch wires.
Comment in
-
Biomechanical analysis of the new torque segment arch (TSA). Comment on the paper by A. Wichelhaus and F.G. Sander in Fortschr. Kieferorthop. 56 (1995), 224-235.J Orofac Orthop. 1996 Aug;57(4):260-7. doi: 10.1007/BF02190239. J Orofac Orthop. 1996. PMID: 8765801 English, German. No abstract available.
Similar articles
-
[Clinical experiences with the torque-segmented arch (TSA)].Fortschr Kieferorthop. 1995 Jul;56(4):194-201. doi: 10.1007/BF02168132. Fortschr Kieferorthop. 1995. PMID: 7649513 Clinical Trial. German.
-
Intrusion mechanics according to Burstone with the NiTi-SE-steel uprighting spring.J Orofac Orthop. 1996 Aug;57(4):210-23. doi: 10.1007/BF02190234. J Orofac Orthop. 1996. PMID: 8765797 English, German.
-
Biomechanical analysis of the new torque segment arch (TSA). Comment on the paper by A. Wichelhaus and F.G. Sander in Fortschr. Kieferorthop. 56 (1995), 224-235.J Orofac Orthop. 1996 Aug;57(4):260-7. doi: 10.1007/BF02190239. J Orofac Orthop. 1996. PMID: 8765801 English, German. No abstract available.
-
[Different orthodontic anchorage systems. A critical examination].Fortschr Kieferorthop. 1993 Aug;54(4):156-71. doi: 10.1007/BF02171574. Fortschr Kieferorthop. 1993. PMID: 8375786 Review. German.
-
Which Orthodontic Wire and Working Sequence Should be Preferred for Alignment Phase? A Review.Turk J Orthod. 2016 Jun;29(2):47-50. doi: 10.5152/TurkJOrthod.2016.160009. Epub 2016 Jun 1. Turk J Orthod. 2016. PMID: 30112474 Free PMC article. Review.
Cited by
-
A new elastic slot system and V-wire mechanics.Angle Orthod. 2017 Sep;87(5):774-781. doi: 10.2319/121516-899. Epub 2017 May 22. Angle Orthod. 2017. PMID: 28530449 Free PMC article.
-
Force-Controlled Biomechanical Simulation of Orthodontic Tooth Movement with Torque Archwires Using HOSEA (Hexapod for Orthodontic Simulation, Evaluation and Analysis).Bioengineering (Basel). 2023 Sep 7;10(9):1055. doi: 10.3390/bioengineering10091055. Bioengineering (Basel). 2023. PMID: 37760157 Free PMC article.
-
Concept and development of a measuring system for in vivo recording of orthodontically applied forces and torques in the multiband technique. Part I.J Orofac Orthop. 1996 Oct;57(5):298-305. doi: 10.1007/BF02197550. J Orofac Orthop. 1996. PMID: 8874174 English, German.
-
Stainless steel and NiTi torque archwires and apical root resorption.J Orofac Orthop. 2021 Jan;82(1):1-12. doi: 10.1007/s00056-020-00244-4. Epub 2020 Sep 1. J Orofac Orthop. 2021. PMID: 32875350 Free PMC article.
-
Biomechanical Simulation of Orthodontic En-Bloc Retraction Comparing Compound Technique and Sliding Mechanics Using a HOSEA Robotic Device.Bioengineering (Basel). 2024 Feb 2;11(2):153. doi: 10.3390/bioengineering11020153. Bioengineering (Basel). 2024. PMID: 38391639 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Research Materials