Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1995 May;49(3):239-48.
doi: 10.1016/0167-5273(95)02308-j.

Physical work capacity with rate responsive ventricular pacing (VVIR) versus dual chamber pacing (DDD) in patients with normal and diminished left ventricular function

Affiliations
Clinical Trial

Physical work capacity with rate responsive ventricular pacing (VVIR) versus dual chamber pacing (DDD) in patients with normal and diminished left ventricular function

J Frielingsdorf et al. Int J Cardiol. 1995 May.

Abstract

To determine the benefit of atrial contribution on work capacity in relation to left ventricular ejection fraction, we studied 17 patients (68 +/- 13 years) with dual chamber pacemakers (DDD) implanted for high degree atrioventricular (AV) block. In random order they were assigned to rate responsive ventricular (VVIR) and to atrial triggered ventricular (VDD) stimulation. Maximum oxygen uptake (max VO2), that correlates best with work capacity, was measured by spiroergometry at a respiratory quotient of 1.1 during treadmill exercise test. Left ventricular ejection fraction at rest was determined by radionuclide ventriculography during VDD-stimulation and an AV delay of 150 ms. There were no differences between these two pacing modes relating heart rate, blood pressure, minute ventilation, exercise duration and maximal work load. In eight patients with an ejection fraction > 50% (60 +/- 10%), but not in nine patients with an ejection fraction < 50% (41 +/- 10%), maximum oxygen uptake was significantly higher (P < 0.01) during atrial triggered ventricular pacing (1440 +/- 533 ml/min) compared with rate responsive ventricular pacing (1328 +/- 536 ml/min). Thus, rate responsive single chamber pacemakers largely enable the same work capacity as dual chamber pacemakers in patients with high degree AV block. Patients with normal left ventricular function may profit most from preserved AV synchrony as shown by the higher maximum oxygen uptake on exercise.

PubMed Disclaimer

Similar articles

Cited by

Publication types