Radiographic measurement of wear in 5 cohorts of patients observed for 5 to 22 years
- PMID: 7671468
Radiographic measurement of wear in 5 cohorts of patients observed for 5 to 22 years
Abstract
Standardized wear measurements using a tablet digitizer were made on long-term serial radiographs for 5 cohorts of total hip replacements to determine any differences in acetabular component polyethylene wear rates. The 5 groups included 4 cemented acetabular component series and 1 cementless acetabular component series. Comparing the rates of linear wear for the 5 groups, 22-mm-head components had similar wear when compared with the 28-mm-head components, both cemented and uncemented, and volumetric wear rates were greater for the cemented 28-mm-head components than for the 22-mm-head components. Although molded 22-mm-head components had less wear than the machined 22-mm-head components, there was no statistically significant difference between the 2. The uncemented metal-backed component with 28-mm-head articulation showed no accelerated wear when compared with the cemented metal-backed components at a shorter 5-year followup. The constant variable in all series was a cemented femoral component.
Similar articles
-
Polyethylene wear in total hip arthroplasty.Clin Orthop Relat Res. 1995 Aug;(317):7-13. Clin Orthop Relat Res. 1995. PMID: 7671498
-
[Radiographic assessment of polyethylene wear in machined versus molded polyethylene in total hip prosthesis].Rev Chir Orthop Reparatrice Appar Mot. 2000 Feb;86(1):10-4. Rev Chir Orthop Reparatrice Appar Mot. 2000. PMID: 10669819 French.
-
Comparison of polyethylene wear in machined versus molded polyethylene.Clin Orthop Relat Res. 1995 Aug;(317):37-43. Clin Orthop Relat Res. 1995. PMID: 7671494
-
Fixation of the acetabular component. The case for cement.Clin Orthop Relat Res. 1997 Nov;(344):207-15. Clin Orthop Relat Res. 1997. PMID: 9372772 Review.
-
Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.Acta Orthop Scand. 2001 Feb;72(1):22-8. doi: 10.1080/000164701753606644. Acta Orthop Scand. 2001. PMID: 11327409 Review.
Cited by
-
Clinical biomechanics of wear in total hip arthroplasty.Iowa Orthop J. 2003;23:1-12. Iowa Orthop J. 2003. PMID: 14575243 Free PMC article.
-
Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.HSS J. 2005 Sep;1(1):31-4. doi: 10.1007/s11420-005-0102-6. HSS J. 2005. PMID: 18751806 Free PMC article.
-
Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.Int Orthop. 2013 Jan;37(1):9-14. doi: 10.1007/s00264-012-1738-8. Epub 2012 Dec 11. Int Orthop. 2013. PMID: 23229800 Free PMC article.
-
Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data.Skeletal Radiol. 2003 Dec;32(12):679-86. doi: 10.1007/s00256-003-0685-2. Epub 2003 Sep 13. Skeletal Radiol. 2003. PMID: 13680199
-
[Impacted acetabular cups].Eur J Orthop Surg Traumatol. 1996 Dec;6(4):217-222. doi: 10.1007/BF03380085. Epub 2017 Mar 10. Eur J Orthop Surg Traumatol. 1996. PMID: 28315100 French.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources