Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler
- PMID: 7673762
- DOI: 10.1007/BF01844705
Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler
Abstract
Intravascular ultrasound (IVUS) and intracoronary Doppler (ICD) were performed in eight patients (54.3 +/- 6.5 years, 6 male) immediately after PTCA and after stenting. ICD was also performed before PTCA. After PTCA, IVUS has demonstrated intimal rupture in all patients. After stenting, IVUS revealed wall wrapping of the intimal flap with a free lumen in all patients. The lumen diameter was 2.42 +/- 0.55 mm after PTCA and was 2.74 +/- 0.49 mm after stenting (p < 0.001). The cross-sectional area increased from 4.70 +/- 1.99 mm2 post-PTCA to 6.40 +/- 2.15 mm2 post-stent (p < 0.005). Coronary flow velocity reserve, calculated by the ratio of mean flow velocity at rest and after intracoronary papaverine administration, increased from 2.05 +/- 1.01 to 2.99 +/- 1.14 after PTCA (p = 0.015); and increased to 4.51 +/- 1.33 after stenting (p < 0.001). The morphological data derived from IVUS correlated with the functional information obtained with ICD. In addition to its established role in bail out situations, stent implantation may be considered when a suboptimal morphological and functional result has been demonstrated.
Similar articles
-
Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation.J Am Coll Cardiol. 1999 Dec;34(7):1899-906. doi: 10.1016/s0735-1097(99)00450-7. J Am Coll Cardiol. 1999. PMID: 10588201 Clinical Trial.
-
Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: a combined intravascular ultrasound Doppler flow and imaging study.J Am Coll Cardiol. 1997 Jun;29(7):1520-7. doi: 10.1016/s0735-1097(97)00082-x. J Am Coll Cardiol. 1997. PMID: 9180114
-
Acute and long-term results of an intravascular ultrasound-guided percutaneous transluminal coronary angioplasty/provisional stent implantation strategy.Am J Cardiol. 1999 Dec 1;84(11):1298-303. doi: 10.1016/s0002-9149(99)00561-5. Am J Cardiol. 1999. PMID: 10614794 Clinical Trial.
-
Intravascular ultrasonography in the evaluation of results of coronary angioplasty and stenting.Curr Opin Cardiol. 1999 Nov;14(6):471-9. doi: 10.1097/00001573-199911000-00004. Curr Opin Cardiol. 1999. PMID: 10579062 Review.
-
Optimal balloon angioplasty versus elective stent implantation.J Am Coll Cardiol. 1999 Dec;34(7):1907-9. doi: 10.1016/s0735-1097(99)00458-1. J Am Coll Cardiol. 1999. PMID: 10588202 Review. No abstract available.
Cited by
-
Prevalence of microvascular disease in patients with significant coronary artery disease.Herz. 1999 Nov;24(7):548-57. doi: 10.1007/BF03044227. Herz. 1999. PMID: 10609162
-
Effect of stenting on coronary flow velocity reserve: comparison of coil and tubular stents.Heart. 1999 Oct;82(4):465-70. doi: 10.1136/hrt.82.4.465. Heart. 1999. PMID: 10490562 Free PMC article.
-
Turbulent flow as a cause for underestimating coronary flow reserve measured by Doppler guide wire.Cardiovasc Ultrasound. 2006 Mar 22;4:14. doi: 10.1186/1476-7120-4-14. Cardiovasc Ultrasound. 2006. PMID: 16553954 Free PMC article. Clinical Trial.
-
Coronary microembolization--its role in acute coronary syndromes and interventions.Herz. 1999 Nov;24(7):558-75. doi: 10.1007/BF03044228. Herz. 1999. PMID: 10609163 Review.