Self-monitoring of blood-glucose. Improvement of diabetic control
- PMID: 76746
- DOI: 10.1016/s0140-6736(78)90855-3
Self-monitoring of blood-glucose. Improvement of diabetic control
Abstract
An accurate pattern of blood-glucose changes in everyday life is the basis for treatment in insulin-dependent diabetes. 69 patients were taught to obtain their own blood-glucose profiles with a 'Reflomat' Boehringer Mannheim) reflectance meter on one working and one rest day, and to repeat these where necessary after adjustment of treatment. 2 did not complete the study satisfactorily. The other 67 produced profiles on 241 dyas. Even patients with a limited education could use the technique accurately and their readings correlated closely with simultaneous laboratory values (r = 0.96). Self-monitoring was especially useful in elucidating problems in diabetic control, preventing hypoglycaemia, and managing diabetic pregnancy. Unlike the measurement of HbA1c which only detects poor diabetic control, self-monitoring also shows how to improve it. Patients found self-monitoring more informative than urine tests; their active involvement in management of their disease resulted in better motivation, greater understanding of diabetes, and a sustained improvement in control. By the end of the study 32 of the 67 patients ahd profiles in which no more than one blood-glucose value exceeded 10 mmol/l. Smaller and more portable machines will make the technique more widely applicable.
Similar articles
-
Home monitoring of blood-glucose. Method for improving diabetic control.Lancet. 1978 Apr 8;1(8067):729-32. doi: 10.1016/s0140-6736(78)90854-1. Lancet. 1978. PMID: 76745
-
Home blood-glucose monitoring: a new approach to the management of diabetes mellitus.Med J Aust. 1980 Dec 27;2(13):713-6. Med J Aust. 1980. PMID: 7010095
-
Management of the pregnant diabetic: home or hospital, with or without glucose meters?Lancet. 1980 May 24;1(8178):1122-4. doi: 10.1016/s0140-6736(80)91564-0. Lancet. 1980. PMID: 6103450 Clinical Trial.
-
Self-monitoring of blood glucose.Med Clin North Am. 1982 Nov;66(6):1227-50. doi: 10.1016/s0025-7125(16)31360-8. Med Clin North Am. 1982. PMID: 6755092 Review. No abstract available.
-
A Perspective on the Accuracy of Blood Glucose Meters During Pregnancy.Diabetes Care. 2018 Oct;41(10):2053-2058. doi: 10.2337/dc18-0833. Diabetes Care. 2018. PMID: 30237233 Review.
Cited by
-
Home blood glucose monitoring: effectiveness in a general population of patients who have non-insulin-dependent diabetes mellitus.J Gen Intern Med. 1993 Nov;8(11):597-601. doi: 10.1007/BF02599711. J Gen Intern Med. 1993. PMID: 8289098
-
Methods of assessing diabetic control.Diabetologia. 1979 Jul;17(1):5-16. doi: 10.1007/BF01222971. Diabetologia. 1979. PMID: 381083 Review.
-
24-hour metabolic profiles in diabetic children.Arch Dis Child. 1980 Feb;55(2):112-7. doi: 10.1136/adc.55.2.112. Arch Dis Child. 1980. PMID: 6990878 Free PMC article.
-
Capillary tubes for blood glucose sampling.Diabetologia. 1982 Dec;23(6):539-40. doi: 10.1007/BF00254307. Diabetologia. 1982. PMID: 7152163 No abstract available.
-
A complication of capillary glucose monitoring.Br Med J (Clin Res Ed). 1986 Sep 6;293(6547):597-8. doi: 10.1136/bmj.293.6547.597-a. Br Med J (Clin Res Ed). 1986. PMID: 3092944 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources