Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1993 Jan;31(1):102-6.
doi: 10.1128/jcm.31.1.102-106.1993.

Comparison of the fluorescent treponemal antibody absorption (FTA-ABS) test with the FTA-ABS double staining test for detection of antitreponemal immunoglobulin M in the 19S fraction of human serum

Affiliations
Comparative Study

Comparison of the fluorescent treponemal antibody absorption (FTA-ABS) test with the FTA-ABS double staining test for detection of antitreponemal immunoglobulin M in the 19S fraction of human serum

G Ozanne et al. J Clin Microbiol. 1993 Jan.

Abstract

A widely used immunoglobulin M (IgM) detection assay for the diagnosis of neonatal congenital syphilis is the fluorescent treponemal antibody absorption test used with fractionated serum (FTA-ABS 19S IgM test). Reading the results of the FTA-ABS test is more cumbersome than reading those of the FTA-ABS double staining (FTA-ABS-DS) test, a confirmatory test for specific IgG. To verify that the FTA-ABS-DS test used with an anti-human IgM conjugate could detect specific IgM in fractionated serum samples (FTA-ABS-DS 19S IgM test), 164 fractionated (QUIK-SEP IgM Isolation System; ISOLAB, Inc., Akron, Ohio) serum specimens from infected neonates or adults or from IgG-seronegative subjects were tested by both techniques. The sensitivity limits of the two tests were assessed with reactive serum samples diluted to an endpoint titer. Samples nonreactive by the FTA-ABS 19S IgM test (n = 74) were either nonreactive (n = 65), minimally reactive (n = 5), or reactive (n = 4) by the FTA-ABS-DS 19S IgM test. Samples minimally reactive by the FTA-ABS 19S IgM test (n = 32) were minimally reactive (n = 1) or reactive (n = 31) by the double staining test. All samples reactive by the FTA-ABS 19S IgM test (n = 58) were also reactive by the FTA-ABS-DS 19S IgM test. There was a directly proportional linear relationship (r = 0.9794) between titers obtained by both tests. FTA-ABS-DS 19S IgM titers were constantly equal to or higher than FTA-ABS 19S IgM titers. Fluorescence intensity reading repeatability was 91.4% for the FTA-ABS-DS 19S IgM test and 81.7% for the FTA-ABS 19S IgM test (P = 0.015). Because the more easily read FTA-ABS-DS 19S IgM test is at least as sensitive as, if not more sensitive than, the FTA-ABS 19S IgM test, it is a good alternative to the latter test for the detection of specific IgM in human fractionated sera for those using fluorescence microscopes with incident light.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Clin Microbiol. 1983 Nov;18(5):1141-5 - PubMed
    1. Sex Transm Dis. 1986 Oct-Dec;13(4):221-7 - PubMed
    1. J Clin Microbiol. 1989 Aug;27(8):1835-40 - PubMed
    1. Clin Lab Med. 1989 Sep;9(3):545-57 - PubMed
    1. J Clin Microbiol. 1990 Feb;28(2):296-302 - PubMed

Publication types

Substances