Characterization of PEG-mediated electrofusion of human erythrocytes
- PMID: 7696475
- PMCID: PMC1225620
- DOI: 10.1016/S0006-3495(94)80722-2
Characterization of PEG-mediated electrofusion of human erythrocytes
Abstract
Polyethylene glycol (PEG) and electrofusion were applied together in a simple and highly efficient cell fusion method. PEG (8000 M(r)) was used to bring human erythrocytes into contact, and a single 4.4 kV/cm, 80 microseconds duration pulse was applied to cell suspensions. The fusion yield (FY) is PEG concentration-dependent. A maximum FY (50%) was found at about 10% PEG. Higher PEG concentrations (> 10%) suppressed FY caused by colloid osmotic shrinkage. Morphological changes, such as colloidal osmotic swelling and shrinking, and the expanding and contraction of fusion lumen, when suspension media were changed from PBS to isotonic 15% dextran solutions, was examined by microscopy. FY was found to depend on both simple osmotic and colloidal-osmotic swelling. From the swelling behavior, we propose two types of electropores: the pre-fusion sites between cell pairs, and electropores on each individual cell connecting intracellular and extracellular space. The latter type is responsible for the colloidal osmotic swelling and shrinking of cell which, together with simple osmotic swelling, is responsible for expanding the pre-fusion sites into fusion lumens. Resealing of electropores resulted in reducing FY, but the FY can be restored by simple osmotic shock. Apparently, PEG plays two opposite roles in this fusion method; one is to promote pre-pulse and post-pulse cell-cell contact, protecting pre-fusion sites, and the other suppresses FY by colloid osmotic shrinkage of cells after pulsing, especially when high PEG concentration is used. 10% PEG 8000 represents the optimal combination of these properties.
Similar articles
-
Electrically induced fusion of mammalian cells in the presence of polyethylene glycol.J Membr Biol. 1994 Aug;141(2):177-82. doi: 10.1007/BF00238251. J Membr Biol. 1994. PMID: 7528803
-
Electrofusion between heterogeneous-sized mammalian cells in a pellet: potential applications in drug delivery and hybridoma formation.Biophys J. 1996 Jul;71(1):479-86. doi: 10.1016/S0006-3495(96)79249-4. Biophys J. 1996. PMID: 8804630 Free PMC article.
-
Studies of cell pellets: II. Osmotic properties, electroporation, and related phenomena: membrane interactions.Biophys J. 1994 Jul;67(1):427-35. doi: 10.1016/S0006-3495(94)80498-9. Biophys J. 1994. PMID: 7522598 Free PMC article.
-
Fluorescence measurements of fusion between human erythrocytes induced by poly(ethylene glycol).Biophys J. 1990 Nov;58(5):1109-17. doi: 10.1016/S0006-3495(90)82453-X. Biophys J. 1990. PMID: 2291937 Free PMC article.
-
Localized osmotic swelling and cell fusion in erythrocytes: possible implications for exocytosis.J Cell Sci. 1988 Dec;91 ( Pt 4):597-601. doi: 10.1242/jcs.91.4.597. J Cell Sci. 1988. PMID: 3255759
Cited by
-
The effect of hydrophilic ionic liquids 1-ethyl-3-methylimidazolium lactate and choline lactate on lipid vesicle fusion.PLoS One. 2013 Dec 31;8(12):e85467. doi: 10.1371/journal.pone.0085467. eCollection 2013. PLoS One. 2013. PMID: 24392011 Free PMC article.
-
High-efficiency loading, transfection, and fusion of cells by electroporation in two-phase polymer systems.Biophys J. 1996 Aug;71(2):1123-30. doi: 10.1016/S0006-3495(96)79314-1. Biophys J. 1996. PMID: 8842249 Free PMC article.
-
Membrane skeleton restraint of surface shape change during fusion of erythrocyte membranes: evidence from use of osmotic and dielectrophoretic microforces as probes.Biophys J. 1995 Dec;69(6):2507-16. doi: 10.1016/S0006-3495(95)80121-9. Biophys J. 1995. PMID: 8599657 Free PMC article.
-
Correlation between electric field pulse induced long-lived permeabilization and fusogenicity in cell membranes.Biophys J. 1998 Apr;74(4):1889-98. doi: 10.1016/S0006-3495(98)77898-1. Biophys J. 1998. PMID: 9545050 Free PMC article.
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources