Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging
- PMID: 7698154
- DOI: 10.1007/BF00997246
Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging
Abstract
Single-photon emission tomography (SPET) using technetium-99m labelled myocardial tracers (e.g. 99mTc-sestamibi) has become one of the most popular myocardial imaging methods for the diagnosis of coronary artery disease (CAD). This prospective study was designed to evaluate the diagnostic performance of 99mTc-sestamibi exercise gated planar myocardial imaging by comparison with both visual and quantitative analyses of SPET. The study was conducted in 115 consecutive patients with known or suspected CAD, including 54 patients with a previous myocardial infarction (MI), referred for exercise testing prior to coronary angiography. Multi-gated planar imaging and SPET were performed after bicycle exercise. The end-diastolic (ED) and SPET images were visually scored (SVi). Myocardial uptake was quantitated on SPET slices using maximum count circumferential profiles (SQu) and defect extent was measured by comparison with gender-matched data sets obtained from 27 controls (< 5% likelihood of CAD). CAD was defined as coronary artery stenosis > 50% and/or regional wall motion abnormality. The cut-off criteria for positivity of the three procedures were determined from receiver operating characteristic (ROC) curves derived from the data of patients without previous MI. The area under the ROC curves was similar for ED, SVi and SQu. This was confirmed by the analysis of sensitivity performed using the ROC curve-derived cut-off criteria, in patients with or without previous MI. SVi was more sensitive than ED in identifying the diseased vessel(s) (ED: 41% vs SVi: 80%; P < 0.0005) but ED was more specific in this respect (ED: 79% vs SVi: 61%; P < 0.0005).(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Comparative study of single-injection, single-acquisition 99mTc-MIBI gated SPET and stress-rest perfusion SPET for the evaluation of myocardial viability after bypass surgery in coronary artery disease.Eur J Nucl Med. 2000 Dec;27(12):1747-53. doi: 10.1007/s002590000386. Eur J Nucl Med. 2000. PMID: 11189935
-
Direct comparison of technetium 99m-sestamibi and technetium 99m-tetrofosmin cardiac single photon emission computed tomography in patients with coronary artery disease.J Nucl Cardiol. 1998 May-Jun;5(3):265-74. doi: 10.1016/s1071-3581(98)90128-3. J Nucl Cardiol. 1998. PMID: 9669581 Clinical Trial.
-
[Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].G Ital Cardiol. 1993 Feb;23(2):127-38. G Ital Cardiol. 1993. PMID: 8491353 Italian.
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
-
Combined exercise radionuclide angiocardiography and single photon emission computed tomography perfusion studies for assessment of coronary artery disease.Semin Nucl Med. 1991 Jul;21(3):223-9. doi: 10.1016/s0001-2998(05)80042-x. Semin Nucl Med. 1991. PMID: 1948112 Review.
Cited by
-
Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.J Nucl Cardiol. 1999 Jan-Feb;6(1 Pt 1):3-10. doi: 10.1016/s1071-3581(99)90058-2. J Nucl Cardiol. 1999. PMID: 10070835
-
Regional myocardial motion and thickening assessed at rest by ECG-gated 99mTc-MIBI emission tomography and by magnetic resonance imaging.Eur J Nucl Med. 1996 Aug;23(8):909-16. doi: 10.1007/BF01084364. Eur J Nucl Med. 1996. PMID: 8753679
-
Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction.J Nucl Cardiol. 1996 Nov-Dec;3(6 Pt 1):464-74. doi: 10.1016/s1071-3581(96)90056-2. J Nucl Cardiol. 1996. PMID: 8989671
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous