Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Dec;20(4):195-201.
doi: 10.1016/0732-8893(94)90003-5.

Use of the polymerase chain reaction for the detection of Chlamydia trachomatis from endocervical and urine specimens in an asymptomatic low-prevalence population of women

Affiliations
Comparative Study

Use of the polymerase chain reaction for the detection of Chlamydia trachomatis from endocervical and urine specimens in an asymptomatic low-prevalence population of women

M Skulnick et al. Diagn Microbiol Infect Dis. 1994 Dec.

Abstract

The Amplicor Chlamydia trachomatis test is a polymerase chain reaction (PCR)-based methodology used for the detection of a cryptic plasmid found in C. trachomatis. It was evaluated in comparison with cell culture and the Microtrak II Chlamydia enzyme immunoassay (EIA) for the detection of C. trachomatis in urogenital specimens from women. Endocervical swabs were collected from 993 women attending the women's unit at the Mount Sinai Hospital in Toronto. In addition, concomitant first void urine specimens were collected from 394 of these women for PCR testing only. As compared with culture of the endocervical specimens, PCR and EIA had a sensitivity, specificity, positive predictive value and negative predictive value of 84.6%, 99.2%, 57.9%, and 99.8% and 61.5%, 99.7%, 72.7%, and 99.5%, respectively. As compared with the secondary gold standard of a positive culture and/or a positive PCR using a primer to the major outer membrane protein the sensitivity, specificity, positive, and negative predictive values for culture were 72.2%, 100%, 100%, and 99.5%, respectively. For the Amplicor PCR and EIA the results were 88.9%, 99.7%, 84.2%, and 99.9% and 61.1%, 99.9%, 91.7%, and 99.6%, respectively. When the urine PCR was compared with the same standard, the test had a sensitivity of 91.7% and a specificity of 99.5%. Based on this study the Amplicor C. trachomatis test was found to be sensitive and specific for the detection of C. trachomatis in both endocervical and urine specimens.

PubMed Disclaimer

Publication types