Quantal analysis based on spectral methods
- PMID: 7708478
- DOI: 10.1007/BF02584026
Quantal analysis based on spectral methods
Abstract
A method for calculating quantal size based on spectral analysis of postsynaptic potential (PSP) amplitude distributions was developed and tested by Monte-Carlo techniques. It was combined with a test to reveal the bias of the estimate of quantal size and to determine whether the peaks in amplitude distributions reflect quantal release or a sampling artifact. Spectral density was computed using fast Fourier transformation after subtraction of a fitted polynomial from the probability density function. The method overestimated quantal size for values less than two standard deviations of noise, indicating that those estimates as well as estimates of quantal size computed for examples of non-quantal distributions are not reliable. This was the case for 34 of 36 sets of sensorimotor excitatory PSPs of the frog, suggesting that most values of the quanta in synapses between primary fibres and lumbar motoneurons are smaller than 70-90 microV.
Similar articles
-
Calibration of an autocorrelation-based method for determining amplitude histogram reliability and quantal size.J Physiol. 1997 Dec 1;505 ( Pt 2)(Pt 2):425-42. doi: 10.1111/j.1469-7793.1997.425bb.x. J Physiol. 1997. PMID: 9423184 Free PMC article.
-
Quantal analysis of excitatory synapses in rat hippocampal CA1 in vitro during low-frequency depression.J Physiol. 1997 Dec 1;505 ( Pt 2)(Pt 2):457-71. doi: 10.1111/j.1469-7793.1997.457bb.x. J Physiol. 1997. PMID: 9423186 Free PMC article.
-
Quantal parameters of "minimal" excitatory postsynaptic potentials in guinea pig hippocampal slices: binomial approach.Exp Brain Res. 1992;89(2):248-64. doi: 10.1007/BF00228242. Exp Brain Res. 1992. PMID: 1320572
-
[Changes in the kinetics of quanta secretion-effective mechanism of synaptic transmission modulation].Ross Fiziol Zh Im I M Sechenova. 2010 Aug;96(8):766-77. Ross Fiziol Zh Im I M Sechenova. 2010. PMID: 20968062 Review. Russian.
-
Quantal analysis and synaptic efficacy in the CNS.Trends Neurosci. 1991 Oct;14(10):439-45. doi: 10.1016/0166-2236(91)90042-s. Trends Neurosci. 1991. PMID: 1722362 Review.
Cited by
-
Calibration of an autocorrelation-based method for determining amplitude histogram reliability and quantal size.J Physiol. 1997 Dec 1;505 ( Pt 2)(Pt 2):425-42. doi: 10.1111/j.1469-7793.1997.425bb.x. J Physiol. 1997. PMID: 9423184 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Miscellaneous