Fracture toughness of human bone under tension
- PMID: 7730389
- DOI: 10.1016/0021-9290(94)00069-g
Fracture toughness of human bone under tension
Abstract
The longitudinal fracture toughnesses of human cortical bone were compared to those of bovine cortical bone to test the hypothesis that although human osteonal bone is significantly weaker and more compliant than primary (plexiform) bone, it is not less tough than primary bone. The fracture toughness indices, critical strain energy release rate (Gc) and critical stress intensity factor (Kc), were determined for human Haversian bone and bovine bone under tension (Mode I) loading using the compact tension method. The effects of thickness, crack growth range and anisotropy on fracture indices for slow stable crack growth in cortical bone were determined. Plane strain assumptions required for application of linear elastic fracture mechanics (LEFM) to bone were investigated. Longitudinal oriented fracture toughness tests were used to assess the crack inhibiting effect of human bone microstructure on fracture resistance. Human bone Kc calculated from the stress concentration formula for 2 and 3 mm thick specimens equaled 4.32 and 4.05 MN m-3/2, respectively. Human bone Gc calculated from the compliance method equaled 827 N m-1 for 2 mm thick specimens and 595 N m-1 for 3 mm thick specimens. It was found that crack growth range, thickness and material assumptions affect fracture toughness. Kc calculated from Gc using an anisotropic relation provided the lowest estimate of Kc and equaled 3.31 MN m-3/2 for 2 mm thick specimens and 2.81 MN m-3/2 for 3 mm thick specimens. Both Kc and Gc were significantly reduced after being adjusted to ASTM standard thickness using ratios determined from bovine bone. The fracture toughness of bovine bone relative to human bone ranged from 1.08 to 1.66. This was compared to the longitudinal strength of bovine bone relative to the longitudinal strength of human bone which is approximately equal to 1.5. We found that even though human bone is significantly weaker than bovine bone, relative to its strength, the toughness of human and bovine bone are roughly similar, but the data were not sufficiently definitive to answer the question of which is tougher.
Similar articles
-
Effect of groove on bone fracture toughness.J Biomech. 1992 Dec;25(12):1489-92. doi: 10.1016/0021-9290(92)90061-5. J Biomech. 1992. PMID: 1491024
-
[Fracture toughness of cortical bone in tension, shear, and tear--a comparison of longitudinal and transverse fracture].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1997 Sep;14(3):199-204. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1997. PMID: 11326832 Chinese.
-
Resistance to crack growth in human cortical bone is greater in shear than in tension.J Biomech. 1996 Aug;29(8):1023-31. doi: 10.1016/0021-9290(96)00009-7. J Biomech. 1996. PMID: 8817369
-
Fracture length scales in human cortical bone: the necessity of nonlinear fracture models.Biomaterials. 2006 Mar;27(9):2095-113. doi: 10.1016/j.biomaterials.2005.09.040. Epub 2005 Nov 4. Biomaterials. 2006. PMID: 16271757 Review.
-
Advances in the fracture mechanics of cortical bone.J Biomech. 1987;20(11-12):1071-81. doi: 10.1016/0021-9290(87)90025-x. J Biomech. 1987. PMID: 3323199 Review.
Cited by
-
Fracture strength and adhesive strength of hydroxyapatite-filled polycaprolactone.J Mater Sci Mater Med. 2008 Feb;19(2):929-36. doi: 10.1007/s10856-007-3016-7. Epub 2007 Aug 1. J Mater Sci Mater Med. 2008. PMID: 17665122
-
A novel videography method for generating crack-extension resistance curves in small bone samples.PLoS One. 2013;8(2):e55641. doi: 10.1371/journal.pone.0055641. Epub 2013 Feb 6. PLoS One. 2013. PMID: 23405186 Free PMC article.
-
Postmortem Change and its Effect on Evaluation of Fractures.Acad Forensic Pathol. 2016 Mar;6(1):28-44. doi: 10.23907/2016.004. Epub 2016 Mar 1. Acad Forensic Pathol. 2016. PMID: 31239871 Free PMC article. Review.
-
Promising trends of bioceramics in the biomaterials field.J Mater Sci Mater Med. 2009 Feb;20(2):447-55. doi: 10.1007/s10856-008-3616-x. Epub 2008 Nov 6. J Mater Sci Mater Med. 2009. PMID: 18987955 Review.
-
Cancellous bone lamellae strongly affect microcrack propagation and apparent mechanical properties: separation of patients with osteoporotic fracture from normal controls using a 2D nonlinear finite element method (biomechanical stereology).Bone. 2008 Jun;42(6):1184-92. doi: 10.1016/j.bone.2008.01.022. Epub 2008 Feb 15. Bone. 2008. PMID: 18378204 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous