Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1995;4(1):34-8.
doi: 10.1007/BF00298416.

Measurement of vertebral rotation: Perdriolle versus Raimondi

Affiliations
Comparative Study

Measurement of vertebral rotation: Perdriolle versus Raimondi

H R Weiss. Eur Spine J. 1995.

Abstract

The measurement of vertebral rotation according to Perdriolle is widely used in the French-speaking and Anglo-American countries. Even in this measurement technique there may be a relatively high estimation error because of the not very accurate grading in steps of 5 degrees. The measurement according to Raimondi seems to be easier to use and is more accurate, with 2 degrees steps. The purpose of our study was to determine the technical error of both measuring methods. The apex vertebra of 40 curves on 20 anteroposterior (AP) radiographs were measured by using the Perdriolle torsion meter and the Regolo Raimondi. Interrater and intrarater reliability were computed. The thoracic Cobb angle was 43 degrees, the lumbar Cobb angle 36 degrees. The average rotation according to Perdriolle was 19.1 degrees thoracic (SD 11.14), 12.7 degrees lumbar (11.21). Measurement of vertebral rotation according to Raimondi showed an average rotation of 20.25 degrees in the thoracic region (11.40) and 13.4 degrees lumbar (10.92). The intrarater reliability was r = 0.991 (Perdriolle) and r = 0.997 (Raimondi). The average intrarater error was 1.025 degrees in the Perdriolle measurement and 0.4 degrees in the Raimondi measurement. Interrater error was on average 3.112 degrees for the Perdriolle measurement and 3.630 degrees for the Raimondi measurement. This shows that both methods are useful tools for the follow-up of vertebral rotation as projected on standard X-rays for the experienced clinical. The Raimondi ruler is easier to use and is slightly more reliable.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Bone Joint Surg Am. 1976 Dec;58(8):1125-9 - PubMed
    1. J Biomech. 1985;18(5):369-78 - PubMed
    1. J Pediatr Orthop. 1990 Jul-Aug;10 (4):527-31 - PubMed
    1. J Pediatr Orthop. 1991 Nov-Dec;11(6):789 - PubMed
    1. Spine (Phila Pa 1976). 1981 Sep-Oct;6(5):460-7 - PubMed

Publication types

MeSH terms

LinkOut - more resources