Estimation of aerobic capacity from submaximal cycle ergometry in women
- PMID: 7752875
Estimation of aerobic capacity from submaximal cycle ergometry in women
Abstract
Simple, valid, and reliable methods of estimating maximal oxygen uptake (VO2max) are needed for epidemiologic studies of physical activity, to evaluate fitness for job performance, and to assist in prescription of exercise. Such estimations in women have not received due research attention. Heart rate responses to submaximal cycle ergometry and VO2max during maximal treadmill and cycle ergometer testing were measured in 37 healthy women aged 19-47 yr (X = 31.7 +/- 7.9). The submaximal test was very reliable on retest (r = 0.92), but overestimated measured treadmill VO2max (X = 2.42 vs 2.23 l.min-1; r = 0.76, SEE = 0.229). The submaximal test also greatly overestimated maximal cycle ergometer VO2max (X = 2.42 vs 2.06 l.min-1; r = 0.70, SEE = 0.340). Similar 8.5% (treadmill) and 18.5% (cycle ergometer) overestimation by the submaximal test were found for VO2max relative to body weight. A simple submaximal exercise test is highly reliable as an estimate of VO2max when used for women. It also provides a reasonably good estimate of treadmill measured VO2max.
Similar articles
-
Prediction of maximal oxygen uptake from submaximal exercise testing in aerobically fit and nonfit men.Aviat Space Environ Med. 1993 Aug;64(8):735-40. Aviat Space Environ Med. 1993. PMID: 8368987
-
Development of a submaximal treadmill jogging test for fit college-aged individuals.Med Sci Sports Exerc. 1993 May;25(5):643-7. Med Sci Sports Exerc. 1993. PMID: 8492693
-
Evaluation of the ACSM submaximal ergometer test for estimating VO2max.Med Sci Sports Exerc. 1995 Sep;27(9):1315-20. Med Sci Sports Exerc. 1995. PMID: 8531631
-
Validity of Submaximal Step Tests to Estimate Maximal Oxygen Uptake in Healthy Adults.Sports Med. 2016 May;46(5):737-50. doi: 10.1007/s40279-015-0445-1. Sports Med. 2016. PMID: 26670455 Review.
-
[Assessment of maximal aerobic and anaerobic power using cycling ergometry].Nihon Rinsho. 2000 Sep;58 Suppl:157-61. Nihon Rinsho. 2000. PMID: 11085107 Review. Japanese. No abstract available.
Cited by
-
A guide to consumer-grade wearables in cardiovascular clinical care and population health for non-experts.NPJ Cardiovasc Health. 2025;2(1):44. doi: 10.1038/s44325-025-00082-6. Epub 2025 Sep 2. NPJ Cardiovasc Health. 2025. PMID: 40909206 Free PMC article. Review.
-
Assessment of Measurement Reliability for the IPN Test in Cardiac Patients.J Clin Med. 2020 May 21;9(5):1552. doi: 10.3390/jcm9051552. J Clin Med. 2020. PMID: 32455568 Free PMC article.
-
Association between self-reported and objectively measured physical fitness level in a middle-aged population in primary care.Prev Med Rep. 2015 May 28;2:462-6. doi: 10.1016/j.pmedr.2015.05.010. eCollection 2015. Prev Med Rep. 2015. PMID: 26844103 Free PMC article.
-
Validation of 2 Submaximal Cardiorespiratory Fitness Tests in Patients With Breast Cancer Undergoing Chemotherapy.Rehabil Oncol. 2016 Oct;34(4):137-143. doi: 10.1097/01.REO.0000000000000030. Epub 2016 Oct 14. Rehabil Oncol. 2016. PMID: 27812433 Free PMC article.
-
Use of Heart Rate Index to Predict Oxygen Uptake - A Validation Study.Int J Exerc Sci. 2020 Dec 1;13(7):1705-1717. doi: 10.70252/THPW3818. eCollection 2020. Int J Exerc Sci. 2020. PMID: 33414886 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous