Is myoglobin useful in the diagnosis of acute myocardial infarction in the emergency department setting?
- PMID: 7785657
- DOI: 10.1093/ajcp/103.6.725
Is myoglobin useful in the diagnosis of acute myocardial infarction in the emergency department setting?
Abstract
The authors evaluated the usefulness of a rapid fluorometric enzyme immunoassay for myoglobin (Myo) for early diagnosis of acute myocardial infarction (AMI) in patients in the emergency department. The rapid fluorometric enzyme immunoassay for myoglobin was performed on timed blood samples collected previously for serial CK and CKMB determinations from 41 patients who initially presented to the ED with chest pain and were subsequently admitted to patient care units. Twenty-two patients were AMI positive and 19 were AMI negative. In 12 patients who were AMI positive, Myo increased rapidly and significantly peaking at 6.53 +/- 5.45 hours, whereas in the other 10 patients who were AMI positive, only the declining slopes of Myo were observed due to late AMI presentation. In the AMI negative group, Myo values were within reference range in 8 and persistently elevated in 11. Using the initial rate of Myo release of 20 ng/mL per hour as criteria of discrimination, this assay has a sensitivity of 90.1% and a specificity of 74%. Available samples for the two patients who were false negative were past the window of Myo release for AMI detection. All five patients who were false positive were associated with various degrees of muscular trauma or renal disorder. The authors conclude that the initial rate of Myo release demonstrates good utility both at early detection and early exclusion of AMI. However, its tissue nonspecificity may not permit AMI recognition in the presence of muscular injury.
Similar articles
-
Myoglobin in the early evaluation of acute chest pain.Am J Clin Pathol. 1995 Oct;104(4):472-6. doi: 10.1093/ajcp/104.4.472. Am J Clin Pathol. 1995. PMID: 7572801
-
Combined cardiac marker approach with adjunct two-dimensional echocardiography to diagnose acute myocardial infarction in the emergency department.Ann Emerg Med. 1996 Jan;27(1):1-7. doi: 10.1016/s0196-0644(96)70288-3. Ann Emerg Med. 1996. PMID: 8572434
-
Serial myoglobin levels for patients with possible myocardial infarction.Acad Emerg Med. 1996 Jun;3(6):590-7. doi: 10.1111/j.1553-2712.1996.tb03469.x. Acad Emerg Med. 1996. PMID: 8727630
-
Rapid MB CK subform assay and the early diagnosis of myocardial infarction.Clin Lab Med. 1997 Dec;17(4):669-83. Clin Lab Med. 1997. PMID: 9439878 Review.
-
Laboratory diagnosis of patients with acute chest pain.Clin Chem Lab Med. 2000 Mar;38(3):187-97. doi: 10.1515/CCLM.2000.027. Clin Chem Lab Med. 2000. PMID: 10905753 Review.
Cited by
-
Microwave-Accelerated and Metal-Enhanced Fluorescence Myoglobin Detection on Silvered Surfaces: Potential Application to Myocardial Infarction Diagnosis.Plasmonics. 2006 Mar;1(1):53-59. doi: 10.1007/s11468-006-9006-7. Epub 2006 Mar 1. Plasmonics. 2006. PMID: 19444320 Free PMC article.
-
Comparison of creatine kinase activity and myoglobin blood level in acute myocardial infarction patients.Bosn J Basic Med Sci. 2006 Feb;6(1):19-23. doi: 10.17305/bjbms.2006.3204. Bosn J Basic Med Sci. 2006. PMID: 16533174 Free PMC article.
-
Microwave-accelerated metal-enhanced fluorescence (MAMEF): application to ultra fast and sensitive clinical assays.J Fluoresc. 2006 Jan;16(1):3-8. doi: 10.1007/s10895-005-0026-z. Epub 2005 Dec 22. J Fluoresc. 2006. PMID: 16374655
-
Biomimetic Prussian Blue Sensor for Ultrasensitive Direct Detection of Myoglobin.Polymers (Basel). 2025 Feb 26;17(5):630. doi: 10.3390/polym17050630. Polymers (Basel). 2025. PMID: 40076122 Free PMC article.
-
Myoglobin immunoassay based on metal particle-enhanced fluorescence.J Immunol Methods. 2005 Jul;302(1-2):26-35. doi: 10.1016/j.jim.2005.04.020. J Immunol Methods. 2005. PMID: 15996681 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous