Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Mar;29(1):66-71.
doi: 10.1136/bjsm.29.1.66.

Reproducibility of cardiorespiratory measurements during submaximal and maximal running in children

Affiliations

Reproducibility of cardiorespiratory measurements during submaximal and maximal running in children

V B Unnithan et al. Br J Sports Med. 1995 Mar.

Abstract

With the increased use of oxygen consumption measurements in clinical and sporting studies, measurement variability has become more important to both the paediatric clinician and the sports scientist. In this study we assessed the reproducibility of cardiorespiratory measurements during submaximal and maximal running in children. Ten healthy, physically active boys (mean(s.d.) age 10.7(0.71) years) performed two submaximal and two maximal running tests within a 4 week period. The submaximal protocol consisted of three 6 minute runs at 7.2, 8.0 and 8.8 km/h. Every attempt was made to minimize the sources of non-biological variability at each testing session. During submaximal exercise, oxygen consumption (VO2), heart rate (HR) and fractional utilization appeared to be the most reliable measures accounting for over two-thirds of the total variation (coefficients of reliability (CR) of 68%, 94% and 82% respectively). Ventilation (Ve) and respiratory exchange ratio (RER) proved to be only moderately reliable accounting for less than half of the total variation (CR 50% and 45% respectively). At maximal exercise, VO2, Ve and time to exhaustion were most reliable, accounting for approximately two-thirds of the total variation (CR 65%, 63% and 63% respectively). Within this test environment, a two visit submaximal assessment was capable of estimating VO2 with a standard error of +/- 1.25 ml/kg/min. Similarly, for maximal testing a two visit assessment estimated peak VO2 with a standard error of +/- 2.28 ml/kg/min. On the evidence of these results a two visit assessment for submaximal and maximal exercise testing seems adequate to estimate the stability of submaximal cardiorespiratory measures and peak VO2 in healthy, normally active boys.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Med Sci Sports. 1976 Spring;8(1):23-5 - PubMed
    1. Clin Sci. 1970 Aug;39(2):247-58 - PubMed
    1. Med Sci Sports Exerc. 1992 Apr;24(4):475-82 - PubMed
    1. Med Sci Sports Exerc. 1991 Aug;23(8):944-8 - PubMed
    1. Med Sci Sports Exerc. 1991 Mar;23(3):378-83 - PubMed

LinkOut - more resources