Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Oct;22(5):431-45.
doi: 10.1007/BF02353864.

Comparison of the Akaike Information Criterion, the Schwarz criterion and the F test as guides to model selection

Affiliations
Comparative Study

Comparison of the Akaike Information Criterion, the Schwarz criterion and the F test as guides to model selection

T M Ludden et al. J Pharmacokinet Biopharm. 1994 Oct.

Abstract

In pharmacokinetic data analysis, it is frequently necessary to select the number of exponential terms in a polyexponential expression used to describe the concentration-time relationship. The performance characteristics of several selection criteria, the Akaike Information Criterion (AIC), and the Schwarz Criterion (SC), and the F test (alpha = 0.05), were examined using Monte Carlo simulations. In particular, the ability of these criteria to select the correct model, to select a model allowing estimation of pharmacokinetic parameters with small bias and good precision, and to select a model allowing precise predictions of concentration was evaluated. To some extent interrelationships among these procedures is explainable. Results indicate that the F test tends to choose the simpler model more often than does either the AIC or SC, even when the more complex model is correct. Also, the F test is more sensitive to deficient sampling designs. Clearance estimates are generally very robust to the choice of the wrong model. Other pharmacokinetic parameters are more sensitive to model choice, particularly the apparent elimination rate constant. Prediction of concentrations is generally more precise when the correct model is chosen. The tendency for the F test (alpha = 0.05) to choose the simpler model must be considered relative to the objectives of the study.

PubMed Disclaimer

References

    1. J Pharmacokinet Biopharm. 1978 Jun;6(3):227-41 - PubMed
    1. J Pharmacokinet Biopharm. 1978 Apr;6(2):165-75 - PubMed
    1. Biopharm Drug Dispos. 1991 Mar;12(2):139-47 - PubMed
    1. J Pharmacokinet Biopharm. 1987 Feb;15(1):75-92 - PubMed
    1. Biochem J. 1983 Apr 1;211(1):23-34 - PubMed

Publication types