Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Jan;56(1):83-7.
doi: 10.1007/BF00298749.

A new rapid and reproducible homologous immunoradiometric assay for amino-terminal parathyroid hormone in the rat

Affiliations

A new rapid and reproducible homologous immunoradiometric assay for amino-terminal parathyroid hormone in the rat

B Rucinski et al. Calcif Tissue Int. 1995 Jan.

Abstract

Measurement of parathyroid hormone (PTH) in the rat is most often performed with competitive ligand radioimmunoassays (RIA) utilizing heterologous antibodies. We report here the validation of a newly developed homologous immunoradiometric assay (IRMA) for rat PTH. Two different goat antibodies to the amino-terminal sequence of rat PTH are utilized; one is immobilized onto plastic beads to capture the PTH molecules and the other is radiolabeled for detection. To test this new IRMA, 30 Sprague-Dawley rats were randomized into three treatment groups to receive by intraperitoneal injection: (1) saline 1 ml/kg (control); (2) calcium chloride 40 mg/kg (hypercalcemic); and (3) EDTA 300 mg/kg (hypocalcemic). Blood samples were taken at 0, 30, 60, 180, and 300 minutes after administration of the assigned treatment for measurement of ionized calcium (Ca2+) and serum PTH. Most of the variance in PTH levels was found to be due to changes in Ca2+ (r2 = 0.780, P < 0.0001). There was also a close temporal relationship between the two, with the highest levels of PTH occurring at the same measured time points as the lowest Ca2+, and vice versa. The measured detection limit of the IRMA was 3 pg/ml with intra- and interassay coefficients of variation of 1.74% and 3.07%, respectively. Serial dilutions with pooled rat serum, synthetic rat PTH-(1-34), and synthetic human PTH-(1-34) showed good parallelism with increased specificity for the pooled and synthetic PTH, despite a degree of crossreactivity with hPTH.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

References

    1. Endocrinology. 1985 Sep;117(3):1230-4 - PubMed
    1. Am J Physiol. 1991 Aug;261(2 Pt 1):E262-8 - PubMed
    1. J Bone Miner Res. 1989 Aug;4(4):577-83 - PubMed
    1. J Biol Chem. 1984 Mar 10;259(5):3320-9 - PubMed
    1. Clin Chem. 1987 Aug;33(8):1364-7 - PubMed

Publication types

MeSH terms

LinkOut - more resources