Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1995 Mar;30(3):186-91.
doi: 10.1097/00004424-199503000-00009.

Conventional film-screen versus computed storage phosphor radiography. Simulated miliary lung disease in an anthropomorphic phantom

Affiliations
Comparative Study

Conventional film-screen versus computed storage phosphor radiography. Simulated miliary lung disease in an anthropomorphic phantom

H Mosser et al. Invest Radiol. 1995 Mar.

Abstract

Rationale and objectives: In this experimental study, the authors examined whether laser printed hardcopies from digital storage phosphor radiographs yield diagnostic performance equal to conventional film-screen radiographs in the detection of simulated miliary disease, using a standardized object.

Methods: A commercially available anthropomorphic chest phantom was used for radiographic evaluation. Miliary disease was simulated by superimposing one to four sheets of millet seeds on the lungs, resembling a miliary disease pattern with varying degrees of detectability. An observer study (receiver-operating characteristic) with eight radiologists was conducted to compare the reader performance using hardcopies of computed storage phosphor radiography versus the conventional film-screen system, optimized for chest x-rays. The digitally generated images were presented as a double-image hardcopy, with a conventionally adopted version and an edge enhanced image version.

Results: When analyzed separately, one out of the eight observers performed slightly better using the conventional films. When treated as a group, analysis of the areas under the receiver-operating characteristic curves demonstrated no significant difference in reader performance for each of the systems under investigation (t = 0.286). The Wilcoxon test could not prove a statistical difference.

Conclusion: Storage phosphor technology is a method that yields equal diagnostic performance as conventional film in evaluating miliary disease of the chest.