Characterization of subcutaneous microvascular blood flow during tilt table-induced neurally mediated syncope
- PMID: 7798529
- DOI: 10.1016/0735-1097(94)00348-t
Characterization of subcutaneous microvascular blood flow during tilt table-induced neurally mediated syncope
Abstract
Objectives: This study aimed to characterize subcutaneous blood flow changes during neurally mediated syncope and to determine whether microvasculature oscillation (vasomotion) is characteristically altered in conjunction with syncopal events.
Background: Marked pallor is commonly associated with neurally mediated syncope. However, little attention has been paid to the evaluation of subcutaneous blood flow and vasomotion in this setting.
Methods: This study utilized laser Doppler flowmetry to assess changes in subcutaneous microvascular blood flow during head-up tilt table testing in 13 patients with syncope and 6 control subjects. Blood flow and vasomotion frequency were measured continuously before, during and after completion of 80 degrees head-up tilt testing (< or = 25-min duration).
Results: Among the 13 patients with syncope, tilt testing reproduced syncopal symptoms in 9 (tilt-positive group) but not in 4 (tilt-negative group). None of the six control subjects developed symptoms during testing. Baseline mean subcutaneous blood flow did not differ significantly among the three groups. However, during upright tilt, blood flow gradually diminished in the tilt-positive group, reaching a nadir of 0.8 +/- 0.33 ml/min per 100 g of tissue (mean +/- SD), but remained relatively constant in the tilt-negative group and control subjects. The difference in mean blood flow response to tilt was statistically significant when the tilt-positive group was compared with either the tilt-negative group or control subjects (p < 0.001). Similarly, baseline blood flow oscillation frequency did not differ significantly in the three subgroups (tilt-positive group 0.2 +/- 0.11 Hz; tilt-negative group 0.2 +/- 0.02 Hz; control subjects 0.2 +/- 0.11 Hz). Subsequently, during tilt testing only the tilt-positive group exhibited increased oscillation frequency; oscillation frequency remained essentially constant throughout the tilt test in the tilt-negative group and control subjects (p < 0.001, tilt-positive group vs. either the tilt-negative group or control subjects).
Conclusions: These findings document an expected diminution of subcutaneous blood flow in association with neurally mediated syncope and indicate that characteristic changes in microvasculature oscillation frequency occur in conjunction with syncopal symptoms. To the extent that microvasculature vasomotion is influenced by neural control, the changes in vasomotion frequency are consistent with relative diminution of peripheral sympathetic neural influence during neurally mediated syncopal episodes.
Similar articles
-
Microvascular blood flow fluctuations during tilt table induced syncope.Comput Cardiol. 2000;27:465-8. Comput Cardiol. 2000. PMID: 14672098
-
Syncope recurrence can better be predicted by history than by head-up tilt testing in untreated patients with suspected neurally mediated syncope.Eur Heart J. 1997 Sep;18(9):1465-9. doi: 10.1093/oxfordjournals.eurheartj.a015473. Eur Heart J. 1997. PMID: 9458453
-
Left ventricular dimensions and autonomic balance during head-up tilt differ between patients with isoproterenol-dependent and isoproterenol-independent neurally mediated syncope.J Am Coll Cardiol. 1995 Jul;26(1):164-73. doi: 10.1016/0735-1097(95)00120-o. J Am Coll Cardiol. 1995. PMID: 7797746
-
Neurally mediated syncopal syndromes: pathophysiological concepts and clinical evaluation.Pacing Clin Electrophysiol. 1997 Feb;20(2 Pt 2):572-84. doi: 10.1111/j.1540-8159.1997.tb06211.x. Pacing Clin Electrophysiol. 1997. PMID: 9058856 Review.
-
Tilt-table testing and syncope.Curr Opin Cardiol. 1992 Feb;7(1):37-45. Curr Opin Cardiol. 1992. PMID: 10149850 Review.
Cited by
-
Implantable diagnostic monitoring devices for evaluation of syncope, and tachy- and brady-arrhythmias.J Interv Card Electrophysiol. 2003 Oct;9(2):137-44. doi: 10.1023/a:1026220020639. J Interv Card Electrophysiol. 2003. PMID: 14574024 Review.
-
Review article: heart rate and blood pressure control in vasovagal syncope.J Interv Card Electrophysiol. 1998 Mar;2(1):25-32. doi: 10.1023/a:1009756521965. J Interv Card Electrophysiol. 1998. PMID: 9869993 Review.
-
Tilt table test: state of the art.Indian Pacing Electrophysiol J. 2003 Oct 1;3(4):239-52. Indian Pacing Electrophysiol J. 2003. PMID: 16943924 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical