Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1995 Jan;76(1):39-44.
doi: 10.1016/s0003-9993(95)80040-9.

Bioenergetic comparison of a new energy-storing foot and SACH foot in traumatic below-knee vascular amputations

Affiliations
Clinical Trial

Bioenergetic comparison of a new energy-storing foot and SACH foot in traumatic below-knee vascular amputations

J M Casillas et al. Arch Phys Med Rehabil. 1995 Jan.

Abstract

In this study, the metabolic performances of a new energy-storing foot (Proteor) and of the solid-ankle cushion heel (SACH) are compared. Twelve patients with traumatic below-knee amputations (mean age: 50.0 +/- 19.9 years) and 12 patients with vascular below-knee amputations (mean age: 73 +/- 7 years) were studied. Oxygen uptake (VO2) was measured in all the subjects on a walkway at a self-selected velocity; only the subjects with traumatic amputation were tested on a level treadmill (progressive speed: 2.4-4 and 6 km/h), and then in two randomized trials: incline (+5%) and decline walking treadmill test at 4 km/h. Vascular explorations were done in the vascular patients: distal pressure measurements, pulse plethysmography, transcutaneous oxygen tension. Free walking was improved in subjects with traumatic amputation using the energy-storing foot (+6%), with a better bioenergetic efficiency (0.24 +/- 0.4mL/kg.m vs 0.22 +/- 0.04mL/kg.m). However, in subjects with vascular amputation, this foot did not produce an increased free velocity nor an improved energy cost. During the level treadmill test, the traumatic amputee subjects showed a decrease of energy expenditure with the new prosthetic foot, more significant at sufficient speed (4 km/h): 17.00 +/- 3.42 vs 14.67 +/- 2.05 mL/kg/min (p < .05). The same effect is shown during the incline (19.31 +/- 2.80 vs 16.79 +/- 2.32 mL/kg/min-p < .02) and decline walking tests (14.13 +/- 3.64 vs 11.81 +/- 1.54mL/kg/min-p < .02). There is no significant difference in cardiocirculatory effects between the two types of prosthetic foot. Despite a lower velocity, the subjects with vascular amputation exceed 70% of the maximal heart rate, with the cardiocirculatory factor being the main cause of walking restriction. The energy-storing foot should be reserved for active and fast walkers, whereas the SACH foot seems more suitable for elderly patients with amputation with a slow walk.

PubMed Disclaimer

Publication types

LinkOut - more resources