Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 1994 Sep 15;18(3):147-55.
doi: 10.1002/cyto.990180306.

Evaluation of flow cytometric methods for diagnosis of chronic granulomatous disease variants under routine laboratory conditions

Affiliations
Free article
Case Reports

Evaluation of flow cytometric methods for diagnosis of chronic granulomatous disease variants under routine laboratory conditions

A Emmendörffer et al. Cytometry. .
Free article

Abstract

Neutrophils from 50 pediatric patients with normal phagocyte functions, from 150 healthy adults, from 10 chronic granulomatous disease (CGD)-patients (4 CGD+), and from 18 X-linked carriers for CGD have been tested for their production of H2O2 using staining with dihydrorhodamine 123 and subsequent flow cytometry. Additionally, neutrophils from three patients with myeloperoxidase deficiency were assessed. Cells were activated to produce H2O2 by the phorbol ester phorbol-myristate-acetate (PMA) and by phagocytosis of Escherichia coli bacteria. To evaluate the sensitivity of the method, H2O2-production by neutrophils which was inhibited by different concentrations of diphenyljodonium (DPI) was measured. The results were compared to those from other methods (NBT-testing, cytochrome c-reduction, and especially chemiluminescence). Normal values and ranges of scatter profile were evaluated in terms of peak channel fluorescence: 97% > 700, x = 840 +/- 59 (S.D.), 97% < 890, for pediatric patients. Normal quantitative values also resulted from small blood samples of infants (< 1 year, n = 6, x = 830 +/- 52). For CGD+ (n = 4) the results were clearly far below the normal range. In indicating decreased production of reactive oxygen intermediates the method was at least as sensitive as lucigenin enhanced chemiluminescence. Cytochrome b558-expression of neutrophils from patients and healthy controls was established by flow cytometry following staining with the monoclonal antibody 7D5. The normal range was 97% > 485, 97% < 680, peak channel fluorescence. We conclude that flow cytometric routine diagnostics of CGD can easily enhance the reliability of recognition and the yield of information about this disease compared to conventional methods.

PubMed Disclaimer

Publication types

LinkOut - more resources