Abstract
The accuracy and precision of a fully automated quantitative coronary angiography (QCA) algorithm for use in a cineless environment were determined in phantom studies and in an in vivo canine preparation. Imaging studies of 118 coronary segments in six anesthetized dogs were compared with measurements of the diameters of casts of the canine coronary arteries produced in physiologic conditions. Regression analysis of phantom vessel diameters against QCA measurements revealed slopes of 0.94 to 0.96 and r values > 0.99. The results of the in vivo studies showed good correlation with the coronary cast diameter measurements, with a slope of 0.969 and an r value of 0.987 for the sets of measurements. The high degree of accuracy obtained in a model representative of the clinical situation demonstrates that QCA methods can be applied reliably in the clinical arena with current digital imaging technology and without cinefilm.
Similar articles
-
Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach.Circulation. 1995 Apr 15;91(8):2174-83. doi: 10.1161/01.cir.91.8.2174. Circulation. 1995. PMID: 7697846
-
A new approach for the quantification of complex lesion morphology: the gradient field transform; basic principles and validation results.J Am Coll Cardiol. 1994 Jul;24(1):216-24. doi: 10.1016/0735-1097(94)90566-5. J Am Coll Cardiol. 1994. PMID: 8006269
-
[Comparison of quantitative coronary arteriography using cinefilm and digital images].J Cardiol. 2001 May;37(5):241-8. J Cardiol. 2001. PMID: 11392892 Japanese.
-
The need for dedicated bifurcation quantitative coronary angiography (QCA) software algorithms to evaluate bifurcation lesions.EuroIntervention. 2015;11 Suppl V:V44-9. doi: 10.4244/EIJV11SVA10. EuroIntervention. 2015. PMID: 25983170 Review.
-
Intravenous coronary angiography with dichromography using synchrotron radiation.Herz. 1996 Apr;21(2):127-31. Herz. 1996. PMID: 8682438 Review.
Cited by
-
The concept of archiving unedited and edited digital coronary angiograms.Int J Card Imaging. 1997 Feb;13(1):35-41. doi: 10.1023/a:1005705523499. Int J Card Imaging. 1997. PMID: 9080237
-
The future of image storage, analysis and communication in the catheterization laboratory.Int J Card Imaging. 1995;11 Suppl 3:145-6. doi: 10.1007/BF01143132. Int J Card Imaging. 1995. PMID: 7594741 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous