The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films
- PMID: 7835525
- DOI: 10.1259/dmfr.23.4.7835525
The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films
Abstract
Studies of observer performance with non-manipulated digital images are almost lacking; nor has the effect of cathode ray tube (CRT) display formats been evaluated. The present study compared the diagnostic accuracy of observers with and without clinical experience in evaluating intra-oral dental films and the corresponding non-manipulated digitized images. Three different-sized (5", 9", 17") monitors were used to study the effect of CRT display format. Artificial radiolucent and radiopaque lesions in dry human mandibles were examined. ROC curve areas were averaged and cross-tabulated according to viewing method and observer experience. For the total group, the non-manipulated digital images resulted in smaller ROC curve areas than the plain films for all CRT formats, with a significantly inferior result for the 17" images (p = 0.036). The increase in diagnostic accuracy of the digital images with decreasing CRT size was not significant (p > 0.05). There was some difference in the mean ROC curve areas between teachers and students, but the effect of the viewing methods was not significant. In terms of observer performance, the experienced observers demonstrated a reduced, and the inexperienced an increased, variability with the digital images compared with conventional film.
Similar articles
-
On-axis and off-axis viewing of images on CRT displays and LCDs: observer performance and vision model predictions.Acad Radiol. 2005 Aug;12(8):957-64. doi: 10.1016/j.acra.2005.04.015. Acad Radiol. 2005. PMID: 16023384
-
Diagnostic usefulness of chest computed radiography--film versus cathode-ray tube images.J Digit Imaging. 1995 Feb;8(1 Suppl 1):25-30. doi: 10.1007/BF03168063. J Digit Imaging. 1995. PMID: 7734536
-
Detection of caries with conventional digital imaging and tuned aperture computed tomography using CRT monitor and laptop displays.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1999 Aug;88(2):234-8. doi: 10.1016/s1079-2104(99)70121-6. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1999. PMID: 10468469
-
Radiology's Achilles' heel: error and variation in the interpretation of the Röntgen image.Br J Radiol. 1997 Nov;70(839):1085-98. doi: 10.1259/bjr.70.839.9536897. Br J Radiol. 1997. PMID: 9536897 Review.
-
[Image evaluation of CRT's--special reference to physical and psychophysical evaluation].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2002 Jan;58(1):28-32. doi: 10.6009/jjrt.kj00003111338. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2002. PMID: 12596828 Review. Japanese. No abstract available.
Cited by
-
Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images.J Digit Imaging. 2000 Feb;13(1):38-45. doi: 10.1007/BF03168339. J Digit Imaging. 2000. PMID: 10696600 Free PMC article.
-
LCD and CRT display of storage phosphor plate and limited cone beam computed tomography images for the evaluation of root canal fillings.Clin Oral Investig. 2009 Mar;13(1):37-42. doi: 10.1007/s00784-008-0211-y. Epub 2008 Jul 30. Clin Oral Investig. 2009. PMID: 18663488
-
In vitro comparison of digital and conventional bitewing radiographs for the detection of approximal caries in primary teeth exposed and viewed by a new wireless handheld unit.Dentomaxillofac Radiol. 2010 Feb;39(2):91-4. doi: 10.1259/dmfr/15182314. Dentomaxillofac Radiol. 2010. PMID: 20100920 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials