Mechanical circulatory support: the Bad Oeynhausen experience
- PMID: 7840701
- DOI: 10.1016/0003-4975(94)00913-r
Mechanical circulatory support: the Bad Oeynhausen experience
Abstract
From September 1987 to February 1994, we treated 147 patients ranging between 11 and 82 years old with different mechanical circulatory support systems. The applied devices were the Bio-Medicus centrifugal pump in 61 patients, the Abiomed BVS System 5000 in 49 patients, the Thoratec ventricular assist device in 42 patients, and the Novacor left ventricular assist device in 7 patients. On the basis of indication for mechanical circulatory support, the patients were divided into three groups: group 1 consisted of 72 patients with postcardiotomy cardiogenic shock; group 2, 50 patients in whom mechanical support was used as a bridge to cardiac transplantation; and group 3 (miscellaneous), 25 patients in cardiogenic shock resulting from acute myocardial infarction (n = 14), acute fulminant myocarditis (n = 3), primary graft failure (n = 2), right heart failure after heart transplantation (n = 3), and acute rejection (n = 3). Time of support ranged from 1 hour to 97 days (mean duration, 10.8 days). Seventy-five patients (51%) were discharged from the hospital. The best survival rate was achieved in group 2 with 72%, followed by group 1 with 44% and then group 3 with 28%. The most frequent complications in group 1 were bleeding (44%), multiple-organ failure (24%), neurologic disorders (18%), and acute renal failure (15%). In group 2, the major complications were bleeding (34%) and cerebrovascular disorders (22%) and in group 3, multiple-organ failure and sepsis (60%) and bleeding (32%).
Similar articles
-
Seven years' experience with the Pierce-Donachy ventricular assist device.J Thorac Cardiovasc Surg. 1988 Dec;96(6):901-11. J Thorac Cardiovasc Surg. 1988. PMID: 3057290
-
Mechanical circulatory support with the Thoratec assist device in patients with postcardiotomy cardiogenic shock.Ann Thorac Surg. 1996 Jan;61(1):314-6. doi: 10.1016/0003-4975(95)01030-0. Ann Thorac Surg. 1996. PMID: 8561596
-
Mechanical circulatory support: reality and dreams experience of a single center.J Extra Corpor Technol. 2004 Jun;36(2):169-73. J Extra Corpor Technol. 2004. PMID: 15334760
-
Mechanical circulatory support for patients with acute-fulminant myocarditis.Ann Thorac Surg. 2001 Mar;71(3 Suppl):S73-6; discussion S82-5. doi: 10.1016/s0003-4975(00)02628-x. Ann Thorac Surg. 2001. PMID: 11265870 Review.
-
Paediatric mechanical circulatory support with Berlin Heart EXCOR: development and outcome of a 23-year experience.Eur J Cardiothorac Surg. 2016 Aug;50(2):203-10. doi: 10.1093/ejcts/ezw011. Epub 2016 Feb 22. Eur J Cardiothorac Surg. 2016. PMID: 26905181 Review.
Cited by
-
Percutaneous ventricular assist devices for cardiogenic shock.Curr Heart Fail Rep. 2008 Sep;5(3):163-9. doi: 10.1007/s11897-008-0025-x. Curr Heart Fail Rep. 2008. PMID: 18752766 Review.
-
Percutaneous ventricular assist devices: new deus ex machina?Minim Invasive Surg. 2011;2011:604397. doi: 10.1155/2011/604397. Epub 2011 Jul 31. Minim Invasive Surg. 2011. PMID: 22091361 Free PMC article.
-
Percutaneous left ventricular assist devices during cardiogenic shock and high-risk percutaneous coronary interventions.Curr Cardiol Rep. 2009 Sep;11(5):369-76. doi: 10.1007/s11886-009-0051-7. Curr Cardiol Rep. 2009. PMID: 19709497 Review.
-
[Microcirculation of kidney and skin during left ventricular assisted circulation--comparative studies of pulsatile and nonpulsatile assists].Jpn J Thorac Cardiovasc Surg. 1998 Dec;46(12):1239-46. doi: 10.1007/BF03217910. Jpn J Thorac Cardiovasc Surg. 1998. PMID: 10037830 Japanese.
Publication types
MeSH terms
LinkOut - more resources
Medical
Research Materials