Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Oct;28(2):143-50.
doi: 10.1016/0300-9572(94)90087-6.

Ventilation caused by external chest compression is unable to sustain effective gas exchange during CPR: a comparison with mechanical ventilation

Affiliations
Comparative Study

Ventilation caused by external chest compression is unable to sustain effective gas exchange during CPR: a comparison with mechanical ventilation

A H Idris et al. Resuscitation. 1994 Oct.

Abstract

Objective: To compare the tidal volume, minute ventilation, and gas exchange caused by mechanical chest compression with and without mechanical ventilatory support during cardiopulmonary resuscitation (CPR) in a laboratory model of cardiac arrest.

Design: A laboratory swine model of CPR was used. Eight animals with and eight animals without mechanical ventilation received chest compression (100/min) for 10 min. Coronary perfusion pressure, tidal volume, and minute ventilation were recorded continuously.

Interventions: Ventricular fibrillation for 6 min without CPR, then mechanical chest compression for 10 min.

Results: During the first minute of chest compression, mean (+/- S.D.) minute ventilation was 11.2 +/- 5.9 l/min in the mechanically ventilated group and 4.5 +/- 2.8 l/min in the group without mechanical ventilation (P = 0.01). Minute ventilation gradually declined to 5.8 +/- 1.4 l/min and 1.7 +/- 1.6 l/min, respectively, during the last minute of chest compression (P < 0.0001). After 10 min of chest compression, mean arterial pH was significantly more acidemic in the group without mechanical ventilation (7.16 +/- 0.13 compared with 7.30 +/- 0.07 units) and PCO2 was higher (62 +/- 19 compared with 35 +/- 9 mmHg). Mixed venous PCO2 was also higher (76 +/- 15 compared with 61 +/- 8 mmHg).

Conclusion: Standard chest compression alone produced measurable tidal volume and minute ventilation. However, after 10 min of chest compression following 6 min of untreated ventricular fibrillation, it failed to sustain pulmonary gas exchange as indicated by significantly greater arterial and mixed venous hypercarbic acidosis when compared with a group receiving mechanical ventilation.

PubMed Disclaimer

Publication types

LinkOut - more resources