Fetal pulse oximetry: a new method of monitoring the fetus
- PMID: 7848233
- DOI: 10.1111/j.1479-828x.1994.tb01263.x
Fetal pulse oximetry: a new method of monitoring the fetus
Abstract
Experimental pulse oximetry devices, similar to the existing systems used in adult and neonatal monitoring, can be used on the fetus to provide safe, and rapid information about oxygenation. They have been calibrated using fetal lambs and validated in human cross-sectional studies. Experiments have shown that fetal oxygen saturation decreases during normal labour, and drops after a uterine contraction especially with oxytocin-induced tachysystole. When the mother is given oxygen the fetal oxygen saturation increases. Readings are effected by caput and movement, and trends seem to be more meaningful than absolute values. Pulse oximetry can predict fetal outcome and a normal oxygen saturation result is specific for a good outcome perhaps even if the CTG is abnormal. However the technique is still experimental and there is insufficient data to support its use as a replacement for fetal blood sampling or a discriminator for an abnormal fetal heart trace.
Similar articles
-
Pulse oximetry during labour--does it give rise to hope? Value of saturation monitoring in comparison to fetal blood gas status.Eur J Obstet Gynecol Reprod Biol. 2003 Sep 22;110 Suppl 1:S132-8. doi: 10.1016/s0301-2115(03)00184-2. Eur J Obstet Gynecol Reprod Biol. 2003. PMID: 12965102
-
[Fetal pulse oximetry: a clinical methodological study].Akush Ginekol (Sofiia). 2000;39(2):47-50. Akush Ginekol (Sofiia). 2000. PMID: 10948624 Bulgarian.
-
Fetal monitoring with pulse oximetry.Br J Obstet Gynaecol. 1991 Jan;98(1):36-41. doi: 10.1111/j.1471-0528.1991.tb10308.x. Br J Obstet Gynaecol. 1991. PMID: 1998630
-
Intrapartum fetal pulse oximetry. Part I: Principles and technical issues.Obstet Gynecol Surv. 2000 Mar;55(3):163-72. doi: 10.1097/00006254-200003000-00025. Obstet Gynecol Surv. 2000. PMID: 10713982 Review.
-
Fetal pulse oximetry.Baillieres Clin Obstet Gynaecol. 1996 Jun;10(2):295-306. doi: 10.1016/s0950-3552(96)80039-3. Baillieres Clin Obstet Gynaecol. 1996. PMID: 8836486 Review.
Cited by
-
Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.J Clin Monit. 1997 Jan;13(1):43-9. doi: 10.1023/a:1007332105965. J Clin Monit. 1997. PMID: 9058252
-
Oxygen in the neonatal ICU: a complicated history and where are we now?Front Pediatr. 2024 May 1;12:1371710. doi: 10.3389/fped.2024.1371710. eCollection 2024. Front Pediatr. 2024. PMID: 38751747 Free PMC article. Review.
-
Supplemental Oxygen in the Newborn: Historical Perspective and Current Trends.Antioxidants (Basel). 2021 Nov 25;10(12):1879. doi: 10.3390/antiox10121879. Antioxidants (Basel). 2021. PMID: 34942982 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources