Comparative Study
. 1994 Nov;7(4):196-207.
doi: 10.1007/BF03168540.

Reduction of false positives in computerized detection of lung nodules in chest radiographs using artificial neural networks, discriminant analysis, and a rule-based scheme

Affiliations
Comparative Study

Reduction of false positives in computerized detection of lung nodules in chest radiographs using artificial neural networks, discriminant analysis, and a rule-based scheme

Y C Wu et al. J Digit Imaging. 1994 Nov.

Abstract

A computer-aided diagnosis (CAD) scheme is being developed to identify image regions considered suspicious for lung nodules in chest radiographs to assist radiologists in making correct diagnoses. Automated classifiers--an artificial neural network, discriminant analysis, and a rule-based scheme--are used to reduce the number of false-positive detections of the CAD scheme. The CAD scheme first detects nodule candidates from chest radiographs based on a difference image technique. Nine image features characterizing nodules are extracted automatically for each of the nodule candidates. The extracted image features are then used as input data to the classifiers for distinguishing actual nodules from the false-positive detections. The performances of the classifiers are evaluated by receiver-operating characteristic analysis. On the basis of the database of 30 normal and 30 abnormal chest images, the neural network achieves an AZ value (area under the receiver-operating-characteristic curve) of 0.79 in detecting lung nodules, as tested by the round-robin method. The neural network, after being trained with a training database, is able to eliminate more than 83% of the false-positive detections reported by the CAD scheme. Moreover, the combination of the trained neural network and a rule-based scheme eliminates 96% of the false-positive detections of the CAD scheme.

PubMed Disclaimer

References

    1. Radiology. 1990 Dec;177(3):857-60 - PubMed
    1. Invest Radiol. 1992 Feb;27(2):124-9 - PubMed
    1. J Digit Imaging. 1993 May;6(2):117-25 - PubMed
    1. Med Phys. 1991 Sep-Oct;18(5):964-71 - PubMed
    1. Invest Radiol. 1990 Sep;25(9):1017-23 - PubMed

Publication types

MeSH terms

LinkOut - more resources