Contamination of dialysis water and dialysate. A survey of 30 centers
- PMID: 7858320
Contamination of dialysis water and dialysate. A survey of 30 centers
Abstract
The concentration of bacteria and endotoxin in dialysis water and dialysate of 30 dialysis centers in western Germany was examined. Water samples were obtained after treatment by reverse osmosis or other processing methods. Collection of dialysis samples for bacterial, fungal, and endotoxin analysis was conducted before and 2 hours after start of hemodialysis. In 17.8% of all water samples analyzed, the AAMI standard was exceeded and bacterial and fungal counts greater than 200 colony forming units/ml were found. In 11.7% of all dialysate samples, higher contamination than the recommendations for dialysate of 2000 colony forming units/ml were found. The concentration of endotoxin in water and dialysate varied between 0 and 95 endotoxin units in the water samples and 0 and 487 endotoxin units/ml in the dialysate samples. In 12.2% of all water sampled, and 27.5% of all dialysate samples, values of 5 endotoxin units/ml were found. No correlation was found between the level of contamination of either water or dialysate in a specific center and the following factors: water processing method (reverse osmosis or others), type of dialysate (acetate of bicarbonate), type of dialysate machine, or method of machine disinfection. In view of these results it is suggested that endotoxin testing, especially in the dialysate, be a part of regular quality control in dialysis.
Similar articles
-
Quality of water in hemodialysis centers in Baghdad, Iraq.Hemodial Int. 2013 Oct;17(4):517-22. doi: 10.1111/hdi.12027. Epub 2013 Mar 5. Hemodial Int. 2013. PMID: 23461710
-
Microbiological quality of water and dialysate in a haemodialysis unit in Ponta Grossa-PR, Brazil.J Appl Microbiol. 2007 Nov;103(5):1791-7. doi: 10.1111/j.1365-2672.2007.03431.x. J Appl Microbiol. 2007. PMID: 17953589
-
Microbial and endotoxin contamination in water and dialysate in the central United States.Artif Organs. 1990 Apr;14(2):85-94. doi: 10.1111/j.1525-1594.1990.tb01601.x. Artif Organs. 1990. PMID: 2350260
-
Ultrapure dialysate: facts and myths.Semin Dial. 2006 Mar-Apr;19(2):115-9. doi: 10.1111/j.1525-139X.2006.00136.x. Semin Dial. 2006. PMID: 16551288 Review.
-
Ultrapure dialysate.Semin Dial. 2004 Nov-Dec;17(6):489-97. doi: 10.1111/j.0894-0959.2004.17617.x. Semin Dial. 2004. PMID: 15660580 Review.
Cited by
-
Validation and applicability of an alternative method for dialysis water and dialysate quality analysis.J Bras Nefrol. 2020 Apr 30;42(2):163-174. doi: 10.1590/2175-8239-JBN-2019-0203. J Bras Nefrol. 2020. PMID: 32364558 Free PMC article.
-
Clinical relevance of abstruse transport phenomena in haemodialysis.Clin Kidney J. 2021 Dec 27;14(Suppl 4):i85-i97. doi: 10.1093/ckj/sfab183. eCollection 2021 Dec. Clin Kidney J. 2021. PMID: 34987788 Free PMC article. Review.
-
Bacteriological Quality of Treated Water and Dialysate in Haemodialysis Unit of A Tertiary Care Hospital.J Clin Diagn Res. 2015 Oct;9(10):DC14-6. doi: 10.7860/JCDR/2015/14681.6692. Epub 2015 Oct 1. J Clin Diagn Res. 2015. PMID: 26557519 Free PMC article.
-
Dyella japonica bacteremia in hemodialysis patient.Emerg Infect Dis. 2007 Aug;13(8):1266-7. doi: 10.3201/eid1308.061204. Emerg Infect Dis. 2007. PMID: 17953113 Free PMC article. No abstract available.
-
Microbiological surveillance and state of the art technological strategies for the prevention of dialysis water pollution.Int J Environ Res Public Health. 2012 Aug;9(8):2758-2771. doi: 10.3390/ijerph9082758. Epub 2012 Aug 2. Int J Environ Res Public Health. 2012. PMID: 23066395 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical