Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Nov;3(6):457-63.
doi: 10.1097/00008469-199411000-00002.

Serodiagnosis of Helicobacter pylori: evaluation of a rapid, miniaturized immunochromatographic test

Affiliations
Comparative Study

Serodiagnosis of Helicobacter pylori: evaluation of a rapid, miniaturized immunochromatographic test

P Cognein et al. Eur J Cancer Prev. 1994 Nov.

Abstract

Diagnosis and successful eradication of Helicobacter pylori infection has been shown to be significantly related to symptom improvement in patients affected by chronic gastritis, duodenal and gastric ulcer. There is, therefore, an increasing need for the development of new, easy to use, reliable and non-invasive techniques to detect this organism. One such test is Flex-Sure (SmithKline Diagnostics Inc., United States), a new, rapid immunochromatographic test which requires a drop of the patient's serum to be placed on the absorbent pad of a strip. If specific antibodies to H. pylori are present a red colour line appears. The present study compared Flex-Sure with a homologous quantitative immunoenzymatic test (HM-CAP, EPI, US) using the same antigen (high molecular weight protein), the second generation GAP test (Bio-Rad, USA), a rapid urease test, culture and histology in a cohort of dyspeptic patients. We produced a semiquantitative visual scale with which to perform this comparison. Our results show that Flex-Sure possesses a sensitivity of 96.1%, a specificity of 73.9%, an overall accuracy of 78.8%, a positive predictive value of 72% and a negative predictive value of 91.6%. It showed a highly significant correlation with histological and cultural results (P < 0.001), and with the other serological tests (P < 0.0001). Based on our data we conclude that Flex-Sure may yield quick (within 4 min), simply readable, qualitative, and according to our colourimetric scale, even semiquantitative results. Furthermore, it does not require any sample dilution, any particular equipment, or any specialized training for the operator.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources