Permissive hypercapnia and intravascular oxygenator in the treatment of patients with ARDS
- PMID: 7864732
- DOI: 10.1111/j.1525-1594.1994.tb03331.x
Permissive hypercapnia and intravascular oxygenator in the treatment of patients with ARDS
Abstract
This open clinical study was aimed at testing the hypothesis that an intravascular oxygenator (IVOX) may help to perform permissive hypoventilation in 10 patients with severe ARDS. After initial evaluation, we tried to reduce ventilator settings before and after IVOX implantation. Before IVOX, poor clinical tolerance and worsening oxygenation did not allow for a significant decrease in ventilator settings. With IVOX, peak inspiratory pressure (PIP) was reduced from 47 to 39 cm H2O (p = 0.005) and minute ventilation from 13 +/- 3.5 to 11 +/- 3 L/min. CO2 removal by IVOX allowed a significant decrease in PaCO2 from 66 +/- 15 to 59 +/- 13 mm Hg. Improvement of oxygenation with IVOX was not significant. Furthermore, interruption of oxygen flow through IVOX did not change oxygenation variables. Tolerance of the IVOX device was good, but insertion of the device was followed by a significant decrease in both cardiac index and pulmonary wedge pressure. In conclusion, IVOX improves tolerance of hypoventilation by limiting hypercapnia in ARDS patients. These preliminary results must be confirmed by a randomized controlled study.
Similar articles
-
Intravascular membrane oxygenation and carbon dioxide removal with IVOX: can improved design and permissive hypercapnia achieve adequate respiratory support during severe respiratory failure?Artif Organs. 1994 Nov;18(11):833-9. doi: 10.1111/j.1525-1594.1994.tb03332.x. Artif Organs. 1994. PMID: 7864733
-
Reduction of ventilator settings allowed by intravenous oxygenator (IVOX) in ARDS patients.Intensive Care Med. 1995 Jan;21(1):11-7. doi: 10.1007/BF02425148. Intensive Care Med. 1995. PMID: 7560467 Clinical Trial.
-
In vivo gas transfer performance of the intravascular oxygenator in acute respiratory failure.Artif Organs. 1994 Nov;18(11):840-5. doi: 10.1111/j.1525-1594.1994.tb03333.x. Artif Organs. 1994. PMID: 7864734
-
Intravascular membrane oxygenation and carbon dioxide removal--a new application for permissive hypercapnia?Thorac Cardiovasc Surg. 1992 Jun;40(3):115-20. doi: 10.1055/s-2007-1020127. Thorac Cardiovasc Surg. 1992. PMID: 1412375 Review.
-
Intravascular membrane oxygenator and carbon dioxide removal devices: a review of performance and improvements.ASAIO J. 1999 Jan-Feb;45(1):41-6. doi: 10.1097/00002480-199901000-00010. ASAIO J. 1999. PMID: 9952005 Review.
Cited by
-
Acute in vivo testing of a respiratory assist catheter: implants in calves versus sheep.ASAIO J. 2003 Jul-Aug;49(4):370-7. doi: 10.1097/01.mat.0000074991.94234.b6. ASAIO J. 2003. PMID: 12918576 Free PMC article.
-
Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter.ASAIO J. 2007 May-Jun;53(3):368-73. doi: 10.1097/MAT.0b013e318031af3b. ASAIO J. 2007. PMID: 17515731 Free PMC article.
-
Evaluation of local gas exchange in a pulsating respiratory support catheter.ASAIO J. 2005 Mar-Apr;51(2):152-7. doi: 10.1097/01.mat.0000153648.11692.d0. ASAIO J. 2005. PMID: 15839440 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources