Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Nov;104(5):801-20.
doi: 10.1085/jgp.104.5.801.

Properties of single cardiac Na channels at 35 degrees C

Affiliations
Comparative Study

Properties of single cardiac Na channels at 35 degrees C

K Benndorf. J Gen Physiol. 1994 Nov.

Abstract

Single Na channel currents were recorded in cell-attached patches of mouse ventricular myocytes with an improved patch clamp technique. Using patch pipettes with a pore diameter in the range of 200 nm, seals with a resistance of up to 4 T omega were obtained. Under those conditions, total noise could be reduced to levels as low as 0.590 pA rms at 20 kHz band width. At this band width, properties of single-channel Na currents were studied at 35 degrees C. Six out of a total of 23 patches with teraohm seals contained channel activity and five of these patches contained one and only one active channel. Amplitude histograms excluding transition points showed heterogenous distributions of levels. In one patch, part of the openings was approximately Gaussian distributed at different potentials yielding a slope conductance of 27 pS. The respective peak open probability at -10 mV was 0.26. The mean open time was determined at voltages between -60 and -10 mV by evaluation of the distribution of the event-related gaps in the center of the baseline noise to be approximately 40 microseconds at -60 mV and 50-74 microseconds between -50 and -10 mV. It is concluded that single cardiac Na channels open at 35 degrees C frequently with multiple levels and with open times in the range of several tens of microseconds.

PubMed Disclaimer

Publication types

Substances