Uniform-size hydrophobic polymer-based separation media selectively modified with a hydrophilic external polymeric layer
- PMID: 7881539
- DOI: 10.1016/0021-9673(94)00899-k
Uniform-size hydrophobic polymer-based separation media selectively modified with a hydrophilic external polymeric layer
Abstract
A simple procedure for the preparation of macroporous hydrophobic styrene-divinylbenzene polymeric separation media with a hydrophilic outer surface has been developed. A hydrophilic monomer and water-soluble polymerization initiator are added to the reaction mixture during the final polymerization step of the preparation of size-monodisperse particles. Because the hydrophobic styrene-divinylbenzene framework of the beads is already formed, and the hydrophilic monomer does not penetrate the pores of the beads that are filled with a hydrophobic porogen, the hydrophilic layer is formed only at the surface of the beads. The hydrophilic monomers used included glycerol monomethacrylate and glycerol dimethacrylate and toluene was used as the porogen for the poly(styrene-co-divinylbenzene) beads. Comparative experiments involving beads with or without a hydrophilic medium showed that the separation selectivity of the media towards hydrophobic solutes remains unchanged. However, the modified medium with a hydrophilic layer could be used to analyse mixtures that also contained large peptide molecules as these do not adsorb at its surface as is the case with the unmodified hydrophobic beads.
Similar articles
-
Preparation of hydrophilic polymer-grafted polystyrene beads for hydrophilic interaction chromatography via surface-initiated atom transfer radical polymerization.J Sep Sci. 2011 Nov;34(22):3115-22. doi: 10.1002/jssc.201100443. Epub 2011 Oct 4. J Sep Sci. 2011. PMID: 21972137
-
Polymeric porogens used in the preparation of novel monodispersed macroporous polymeric separation media for high-performance liquid chromatography.Anal Chem. 1992 Jun 1;64(11):1232-8. doi: 10.1021/ac00035a008. Anal Chem. 1992. PMID: 1621992
-
Aqueous size exclusion chromatography in semimicro and micro-columns by newly synthesized monodisperse macroporous hydrophilic beads as a stationary phase.J Chromatogr A. 2012 Feb 10;1224:43-50. doi: 10.1016/j.chroma.2011.12.043. Epub 2011 Dec 19. J Chromatogr A. 2012. PMID: 22218328
-
New formats of polymeric stationary phases for HPLC separations: molded macroporous disks and rods.J Mol Recognit. 1996 Sep-Dec;9(5-6):326-34. doi: 10.1002/(sici)1099-1352(199634/12)9:5/6<326::aid-jmr303>3.0.co;2-g. J Mol Recognit. 1996. PMID: 9174906 Review.
-
Porous polymer monoliths: an alternative to classical beads.Adv Biochem Eng Biotechnol. 2002;76:87-125. doi: 10.1007/3-540-45345-8_3. Adv Biochem Eng Biotechnol. 2002. PMID: 12126272 Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources