Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Jan;50(1):14-7.
doi: 10.1136/thx.50.1.14.

Use of elastin fibre detection in the diagnosis of ventilator associated pneumonia

Affiliations

Use of elastin fibre detection in the diagnosis of ventilator associated pneumonia

M el-Ebiary et al. Thorax. 1995 Jan.

Abstract

Background: Elastin fibre detection could be a simple and reliable marker of ventilator associated pneumonia. To confirm this, a prospective study was undertaken to evaluate the diagnostic yield of elastin fibre detection in the diagnosis of ventilator associated pneumonia.

Methods: Seventy eight mechanically ventilated patients were evaluated by examining endotracheal aspirates for the presence of elastin fibres. All patients were previously treated with antibiotics. Quantitative bacterial cultures of endotracheal aspirates and protected specimen brush samples were also performed. Patients were classified into three diagnostic categories: group 1, definite pneumonia (n = 25); group 2, probable pneumonia (n = 35); and group 3, controls (n = 18).

Results: Patients with definite and probable pneumonia were grouped together. The presence of elastin fibres in endotracheal aspirate samples was more frequent in groups 1 and 2, being found in 19 of the 60 patients compared with five of the control group. Although the presence of elastin fibres had a low sensitivity (32%), it was a reasonably specific marker (72%) of pneumonia. This specificity increased to 86% and 81% respectively when only Gram negative bacilli and Pseudomonas aeruginosa pneumonia were considered. Again, calculated sensitivity was 43% and 44% when analysing cases infected by Gram negative bacilli and Ps aeruginosa, respectively. The negative predictive value of the detection of elastin fibres in pneumonia caused by Ps aeruginosa was 81%. Detection was more frequent with infection by Gram negative bacilli (14/19), particularly with Ps aeruginosa (8/14). By contrast, pneumonia due to Gram positive cocci or non-bacterial agents uncommonly resulted in positive elastin fibre preparations (4/19, 21%). When analysing patients with and without chronic obstructive pulmonary disease, the diagnostic value of elastin fibre detection did not change.

Conclusions: Potassium hydroxide preparation of elastin fibres is a rapid and simple specific marker of ventilator associated pneumonia and may be a useful technique to help diagnose pulmonary infections in mechanically ventilated patients, although this assessment is at present limited to patients without adult respiratory distress syndrome.

PubMed Disclaimer

References

    1. Am Rev Respir Dis. 1979 Mar;119(3):337-43 - PubMed
    1. Am J Respir Crit Care Med. 1994 Aug;150(2):565-9 - PubMed
    1. Chest. 1983 Jun;83(6):885-9 - PubMed
    1. Ann Intern Med. 1983 Sep;99(3):293-8 - PubMed
    1. Chest. 1984 Jun;85(6):763-6 - PubMed