Abstract
This study simultaneously compared the standard Kety-Schmidt and the modified xenon-133 (133Xe) clearance techniques for measuring cerebral blood flow (CBF) and cerebral metabolic rate for oxygen (CMRO2) during cardiac operations. The validity of the CBF method is important because our management of the patient during cardiopulmonary bypass (CPB) is based, in part, on our understanding of the cerebral hemodynamics during CPB. In 20 patients undergoing coronary artery bypass grafting, CBF and CMRO2 were determined by both methods. Measurements were made before onset of CPB and once during CPB. Ten patients underwent CPB with systemic normothermia (37 degrees C) and 10 with systemic hypothermia (27 degrees C). Anesthesia consisted of fentanyl and midazolam. CPB pump flows were kept at 2.2 to 2.4 L.min-1.m-2 and alpha-stat pH management was used. Xenon-133 clearance significantly underestimated CBF and CMRO2 relative to the Kety-Schmidt technique before CPB and at both bypass temperatures. Values obtained by 133Xe clearance were approximately 50% of that measured by the Kety-Schmidt method. The modified 133Xe technique as typically used during cardiac operations does not appear to measure CBF accurately; this leads to corresponding errors in CMRO2 calculations. Determination of CMRO2 and cerebral autoregulatory function during cardiac operations appears to be more appropriate if based on the more direct Kety-Schmidt technique. Accordingly, our management of CPB with respect to cerebral perfusion as it has been determined by the modified 133Xe clearance method may require reassessment.
Comment in
-
Cerebral blood flow values during cardiopulmonary bypass: relatively absolute or absolutely relative?Ann Thorac Surg. 1995 Mar;59(3):558-61. doi: 10.1016/0003-4975(95)00028-3. Ann Thorac Surg. 1995. PMID: 7887688 No abstract available.
Similar articles
-
Cerebral blood flow and oxygen metabolism measured with the Kety-Schmidt method using nitrous oxide.Acta Anaesthesiol Scand. 2009 Feb;53(2):159-67. doi: 10.1111/j.1399-6576.2008.01788.x. Epub 2008 Dec 5. Acta Anaesthesiol Scand. 2009. PMID: 19076112
-
[Measurement of human cerebrovascular circulation. Comparison of Kety-Schmidt technique with the intravenous 133-xenon clearance technique].Anaesthesist. 1996 Nov;45(11):1030-6. doi: 10.1007/s001010050336. Anaesthesist. 1996. PMID: 9012297 Clinical Trial. German.
-
Cerebral blood flow values during cardiopulmonary bypass: relatively absolute or absolutely relative?Ann Thorac Surg. 1995 Mar;59(3):558-61. doi: 10.1016/0003-4975(95)00028-3. Ann Thorac Surg. 1995. PMID: 7887688 No abstract available.
-
Toward Understanding Cerebral Blood Flow during Cardiopulmonary Bypass: Implications for the Central Nervous System.Anesthesiology. 2019 Apr;130(4):609-613. doi: 10.1097/ALN.0000000000002580. Anesthesiology. 2019. PMID: 30875356 Review.
-
Cerebral blood flow and metabolism during cardiopulmonary bypass.Anesth Analg. 1993 Apr;76(4):849-65. doi: 10.1213/00000539-199304000-00029. Anesth Analg. 1993. PMID: 8466029 Review.
Cited by
-
Multimodal brain monitoring in fulminant hepatic failure.World J Hepatol. 2016 Aug 8;8(22):915-23. doi: 10.4254/wjh.v8.i22.915. World J Hepatol. 2016. PMID: 27574545 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous