Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Dec;8(12):1715-20.
doi: 10.1097/00002030-199412000-00012.

Sensitivity of HIV-antibody assays determined by seroconversion panels

Affiliations
Comparative Study

Sensitivity of HIV-antibody assays determined by seroconversion panels

N T Constantine et al. AIDS. 1994 Dec.

Abstract

Objectives: To determine the sensitivity of HIV-antibody assays for detecting low levels of HIV antibody using seroconversion and other panels containing plasma of varying titres.

Methods: Eight HIV-antibody assays, available under the World Health Organization bulk-procurement agreement, were evaluated on sets of sequential plasma samples derived from 11 individuals who had recently become HIV-infected (seroconversion panels). In addition, two non-seroconversion panels, consisting of low performance (titre) and mixed titre samples were used to further define the sensitivity of the assays. The eight assays included two rapid tests, one simple test, and five enzyme-linked immunosorbent assays (ELISA).

Results: On average, the eight assays detected antibody 0.5-4.8 days later than the reference test (Abbott HIV-1/HIV-2 3rd generation ELISA); these differences were statistically significant for six of the eight tests. All tests performed well on the low performance and mixed titre panels. All eight assays also had comparable sensitivity to that of the reference test on a large panel of known positive plasma. The additional risk of missing an infectious unit of blood during seroconversion by using the least sensitive rather than the reference test was estimated to be 1 in 7600 and 1 in 76 million at annual HIV incidence rates of 1 and 0.0001%, respectively. The cost of eliminating this additional risk by using the reference test is between US$ 15,150 and 151 million per unit detected at the above incidence rates.

Conclusions: Although there are differences in sensitivity between the assays when used to test blood from individuals during the course of seroconversion, the differences are small, and all eight tests are appropriate for use as screening tests.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources