Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Jan 15;73(2):164-9.
doi: 10.1016/0002-9149(94)90208-9.

Comparison of dobutamine and exercise using technetium-99m sestamibi imaging for the evaluation of coronary artery disease

Affiliations
Comparative Study

Comparison of dobutamine and exercise using technetium-99m sestamibi imaging for the evaluation of coronary artery disease

S D Herman et al. Am J Cardiol. .

Abstract

Studies using dobutamine thallium-201 myocardial perfusion imaging have suggested a high sensitivity and specificity for the detection of coronary artery disease. However, few data are available comparing dobutamine with exercise stress for the detection and localization of perfusion defects. This study compared the effects of dobutamine and exercise stress using technetium-99m sestamibi single-photon emission computed tomographic imaging in the same patients in a prospective crossover trial. Twenty-four patients with a high likelihood of coronary artery disease underwent tomographic myocardial imaging at rest, after symptom-limited treadmill exercise, and after intravenous dobutamine (maximum 30 micrograms/kg/min). Tomograms of the left ventricle were divided into 20 segments and were interpreted without knowledge of patient identity or stress protocol. Dobutamine was well tolerated by all patients. Segment-by-segment concordance between exercise and dobutamine images was highly significant (kappa = 0.56, p < 0.0001). Global first-order agreement (normal vs abnormal) between exercise and dobutamine studies was 96% (kappa = 0.65, p = 0.02); global second-order agreement (normal vs fixed vs ischemic defect) was 88% (kappa = 0.45, p = 0.02). Regional first- and second-order agreement were 96 and 93%, respectively (p < 0.001 for both). Twenty patients underwent coronary angiography. Comparisons between exercise and angiography and between dobutamine and angiography were similar for both global agreement (95 vs 100%, p = NS) and regional agreement (77 vs 72%, p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

LinkOut - more resources