Free light chains of immunoglobulins: clinical laboratory analysis
- PMID: 7923764
Free light chains of immunoglobulins: clinical laboratory analysis
Abstract
The increased sensitivity of immunofixation electrophoresis (IFE) over prior electrophoretic methods has led to renewed interest in the study of free light chains. Here, we discuss problems associated with the identification of monoclonal free light chains (Bence Jones proteins) in urine. Besides reviewing the nature of the sample specimens and the assays themselves, we discuss the physiology, biochemistry, genetics, and immunological properties of these molecules. Direct measurement of kappa/lambda ratios may ultimately be useful, but all commercial methods available now lack sufficient sensitivity. IFE is the preferred method because of its sensitivity and ease of interpretation. There are, however, difficulties associated with the interpretation of urinary IFE patterns, because the technique does not include an intrinsic mechanism for antibody-antigen titration and because of its great sensitivity in the absence of quantification. Problems of interpretation are discussed.
Similar articles
-
Studies of Bence Jones proteins by immunonephelometry.Ann Clin Lab Sci. 1992 Mar-Apr;22(2):100-9. Ann Clin Lab Sci. 1992. PMID: 1562164
-
Comparison of the sensitivity of 2 automated immunoassays with immunofixation electrophoresis for detecting urine Bence Jones proteins.Clin Chem. 2005 Aug;51(8):1505-7. doi: 10.1373/clinchem.2004.045880. Clin Chem. 2005. PMID: 16040842 No abstract available.
-
Restricted electrophoretic heterogeneity of immunoglobulin light chains in urine: a cause for confusion with Bence Jones protein.Clin Chem. 1991 Sep;37(9):1570-4. Clin Chem. 1991. PMID: 1909942
-
Immunochemical quantification of free immunoglobulin light chains from an analytical perspective.Clin Chem Lab Med. 2006;44(5):522-32. doi: 10.1515/CCLM.2006.118. Clin Chem Lab Med. 2006. PMID: 16681419 Review.
-
Monoclonal free light chain detection and quantification: Performances and limits of available laboratory assays.Clin Biochem. 2021 Sep;95:28-33. doi: 10.1016/j.clinbiochem.2021.05.006. Epub 2021 May 12. Clin Biochem. 2021. PMID: 33991536 Review.
Cited by
-
Elevated immunoglobulin levels in the cerebrospinal fluid from lupus-prone mice.J Neuroimmunol. 2005 Aug;165(1-2):104-13. doi: 10.1016/j.jneuroim.2005.04.022. J Neuroimmunol. 2005. PMID: 15972238 Free PMC article.
-
Differences in kappa to lambda (kappa:lambda) ratios of serum and urinary free light chains.Clin Exp Immunol. 1998 Feb;111(2):457-62. doi: 10.1046/j.1365-2249.1998.00487.x. Clin Exp Immunol. 1998. PMID: 9486419 Free PMC article.
-
Polyclonal free light chains: a biomarker of inflammatory disease or treatment target?F1000 Med Rep. 2013;5:4. doi: 10.3410/M5-4. Epub 2013 Feb 1. F1000 Med Rep. 2013. PMID: 23413370 Free PMC article.
-
Comparison of serum free light chain and urine electrophoresis for the detection of the light chain component of monoclonal immunoglobulins in light chain and intact immunoglobulin multiple myeloma.Haematologica. 2016 Mar;101(3):356-62. doi: 10.3324/haematol.2015.126797. Epub 2015 Dec 3. Haematologica. 2016. PMID: 26635032 Free PMC article. Clinical Trial.
-
Novel Approach to Rule-Out Unnecessary Urine Bence Jones Protein Testing: A Serum Free Light Chain Algorithm.Diagnostics (Basel). 2025 Feb 21;15(5):525. doi: 10.3390/diagnostics15050525. Diagnostics (Basel). 2025. PMID: 40075773 Free PMC article.