Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994;67(3):274-9.
doi: 10.1159/000187979.

Clinical value of DMSA planar and single photon emission computed tomography as an initial diagnostic tool in adult women with recurrent acute pyelonephritis

Affiliations
Comparative Study

Clinical value of DMSA planar and single photon emission computed tomography as an initial diagnostic tool in adult women with recurrent acute pyelonephritis

S B Kim et al. Nephron. 1994.

Abstract

Routine DMSA scintigraphy, ultrasound (US) of the kidney, intravenous pyelography (IVP) and voiding cystoureterography (VCU) were performed in 27 consecutive adult women with recurrent acute pyelonephritis (APN) during a 12-month follow-up. Both planar and single photon emission computed tomography (SPECT) images were obtained for DMSA scan. DMSA scans were repeated in those patients with abnormal initial scan. DMSA-SPECT showed normal findings in 2, single renal cortical detect (RCD) in 9 and multiple RCD in 16 (including nonvisualization in 2). Of the 11 kidneys with normal findings or single RCD on DMSA-SPECT, only 1 (9%) showed vesicoureteral reflux (VUR) on VCU (grade I). A large proportion of those with multiple RCDs showed abnormal findings on IVP (44%, 7/16), US (38%, 6/16) or VCU (31%, 5/16); 63% in any of these three studies. 5 of 6 patients with VUR had multiple RCDs on DMSA-SPECT, and 3 of these 5 showed no abnormality on IVP or US. 7 patients who needed other managements besides initial standard antibiotic treatment had multiple RCDs on DMSA-SPECT. 15 normal women were also studied and showed normal DMSA-SPECT, US and IVP, in all cases. Follow-up DMSA-SPECT was done in 16 patients (7 with single RCD, 9 with multiple RCD). All 7 patients with single RCD showed improvement, in those with multiple RCDs improvement was observed in 2, no change in 7 on follow-up studies. We conclude: (1) DMSA-SPECT is a useful initial diagnostic tool in adult women with recurrent APN to identify patients who need more extensive radiological studies.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources