Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 Nov;128(5):896-902.
doi: 10.1016/0002-8703(94)90586-x.

Radiofrequency ablation of left-sided accessory pathways: transaortic versus transseptal approach

Affiliations
Clinical Trial

Radiofrequency ablation of left-sided accessory pathways: transaortic versus transseptal approach

A S Manolis et al. Am Heart J. 1994 Nov.

Abstract

The aim of this study was to compare the efficacy of transaortic (n = 54) and transseptal (n = 28) techniques during radiofrequency (RF) ablation of left accessory pathways (n = 75) in both left posteroseptal and free-wall locations in 73 consecutive patients (mean age 32 +/- 15 years). The transseptal approach included transseptal puncture and use of a retained long sheath in the left atrium (n = 24) or direct insertion of the mapping/ablation catheter via a patent foramen ovale (n = 4). Transseptal RF ablation was used as the primary method in 23 patients or at a separate session after the transaortic RF ablation failed in 5 patients. Transaortic RF ablation was used as primary method in 50 patients and after failed transseptal ablation in 4 patients. Transaortic ablation was successful in 47 (87%) of 54 procedures, transseptal ablation in 24 (86%) of 28 procedures, with total RF ablation success in 70 (96%) of 73 patients. The transseptal puncture/long sheath method was successful in 23 (96%) of 24 patients. This latter technique resulted in more stable positioning and easier manipulation of the ablation catheter. Switching from transseptal puncture/long sheath to transaortic technique was needed in 1 of 24 patients, from transseptal/patent foramen ovale approach to the transaortic route in 3 of 4 patients, and from the transaortic to the transseptal approach at a separate session in 5 patients. The age of patients and number of RF lesions were similar in the two groups. Fluoroscopy time was lower for the transseptal group (81 +/- 57 vs 121 +/- 81 min; p < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

LinkOut - more resources